TMP91C824
91C824-223
4.6
Event Counter (TA0IN)
Variable
10 MHz
27 MHz
Symbol Parameter
Min Max
Min
Max
Min
Max
Unit
t
VCK
Clock Period
8X
+
100
900
396
ns
t
VCKL
Clock Low Level Width
4X
+
40
440
188
ns
t
VCKH
Clock High Level Width
4X
+
40
440
188
ns
4.7 Interrupt,
Capture
(1)
NMI
, INT0 to INT3 Interrupts
Variable
10 MHz
27 MHz
Symbol
Parameter
Min Max
Min
Max
Min
Max
Unit
t
INTAL
NMI
, INT0 to INT3 Low level width
4X
+
40
440
188
ns
t
INTAH
NMI
, INT0 to INT3 High level width
4X
+
40
440
188
ns