Domestic Hot Water Heat Pump Service Manual
6
2.0 Specifications
Physical data
Domestic Hot Water Heat Pump
HWS-G1901CN*R-E
HWS-G2601CN*R-E
HWS-G1901ENXR-E
HWS-G2601ENXR-E
Dimensions (Height x Diameter)
mm
1600x620
1960x620
1600x620
1960x620
Weight (dry / wet)
kg
91 / 281
106/356
107/297
126/376
Nominal insulation thickness
mm
50
50
50
50
Refrigerant
R134A
R134A
R134A
R134A
Refrigerant charge
kg
1.2
1.28
1.2
1.28
Refrigerant charge CO2 equivalent
ton
1.70
1.80
1.70
1.80
Water connections (cold & hot water)
inch
3/4
3/4
3/4
3/4
Water connections (entry angle)
deg.
45 / 180
45 / 180
45 / 180
45 / 180
Condensates water connections
mm
Ø19
Ø19
Ø19
Ø19
Max water side operating pressure
Mpa
0.6
0.6
0.6
0.6
Power supply
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
Performance data
Domestic Hot Water Heat Pump
HWS-G1901CN*R-E
HWS-G2601CN*R-E
HWS-G1901ENXR-E
HWS-G2601ENXR-E
Energy Class
-
A+
A+
A+
A+
COP at Air7°C W10°C-52,9°C (EN16147)
-
3.57
3.69
3.57
3.69
Heat up time (A7°C W10°C-53,5°C)
hh:mm
06:27
09:12
06:27
09:12
COP at Air20°C W10°C-52,9°C (EN16147)
-
4.13
4.2
4.13
4.2
Heat up time (A20°C W10°C-53,5°C)
hh:mm
05:15
07:09
05:15
07:09
Cylinder volume
l
190
260
184
252
V40 volume (W52.9°C)
l
247
347
234
331
Maximum Qty of water by electric heater
only
l (%)
75 (40%)
130 (50%)
75 (40%)
130 (50%)
Maximum water temperature
°C
60
60
60
60
Corrosion protection
Magnesium anode
Magnesium anode
Magnesium anode
Magnesium anode
Heat pump operating range (min/max)
°C
-7 / +40
-7 / +40
-7 / +40
-7 / +40
Electrical heater Power
W
1500
1500
1500
1500
Maximum Power input
W
2185
2185
2185
2185
Auxiliary Power input (Paux)
W
1.61
1.61
1.61
1.61
Standby Power input (Pes)
W
17
20
17
20
Sound power level - Air7°C W10°C-52,9°C
(EN16147)
dB(A)
49
49
49
49
Sound power level - Air20°C W10°C-52,9°C
(EN16147)
dB(A)
55.6
55.6
55.6
55.6
Airflow rate nominal (min - max)
m
3
/h
450 (0 - 800)
450 (0 - 800)
450 (0 - 800)
450 (0 - 800)
Maximum fan power
W
85
85
85
85
Maximum external static pressure
Pa
200
200
200
200
Air duct connections
mm
Ø160
+Ø160
Ø160
Ø160
Minimum room volume (non-ducted unit)
m
3
60
60
60
60
Fan Curve
The graph shows the external static pressure vs airflow
at different fan speeds.
In order to assure an efficient operation, it is suggested
to keep the external pressure drops below 200 Pa.