Domestic Hot Water Heat Pump Service Manual
54
Code
Set point
name
Description
Range
Factory
setting
B5
OFF
The PV function is not active. If this function is activated, the heat pump
and the electric heater can start only if the input voltage in GC1 (0-10V) is
higher than D20/D21 (PV min Voltage HP/EL) for longer than D22 (PV min
time).
OFF /
ECO /
STORAGE
ECO
PV ECO
The PV function allows for water heating only with the heat pump until
temperature set point defined by the MODE of operation is reached.
PV
STORAGE
The PV function allows for water heating to the maximum temperature
level, giving priority to the operation of the heat pump if the BOOST or
BACK UP mode is not active. The heat pump operates alone until the max
allowed temperature for the heat pump operation D33 (T HP Max) is
reached. The electric heater operates only from D33 to the maximum
allowable temperature D9 (Water T max).
B6
Solar
The Solar function allows the water to be heated up by the solar collector,
activating a water pump controlled by the extra relay (GP1). The pump
starts when BT5 > BT3 + D24 (Solar DT min). The pump stops if the
temperature in the tank goes above D23 (Solar T max) or if BT5 is below
BT3.
OFF/ON
OFF
B7
Floor
The floor heating function activates an external circulation pump. If the
temperature at the bottom of the tank BT4 (T water b) is higher than the
setting menu D25 (Floor T start) the floor heating function is activated.
If the extra temperature BT5 (T Extra) is higher than the floor heating
temperature (B8 T floor) the circulation pump (Extra relay GP1) stops.
OFF/ON
OFF
B8
Floor T
The desired floor heating temperature in °C with hysteresis of 1K.
15 - 40
35
B9
Cooling
The Cooling function can be activated. See installer menu D28 (Cooling
type).
OFF/ON
OFF
B10
Cooling T
The air temperature set point (°C) below which the heat pump stops,
when the unit is in the Cooling function.
10 - 30
21
10.1.5 General
The general section collects all the standard settings that have little or no effect on the heat
pump operation, except for the menu item Reset.
Activating the Reset function brings all the set points to the factory settings value. The set
points of the General menu are described in the Table below
Code
Set point
name
Description
Range
Factory
setting
C0
Reset
The set points in the user menu are reset. The more advanced
settings can be reset only from the installer menu.
The information as number of hours of the compressor and fan cannot
be reset
OFF/ON
OFF
C1
Info
The software version is displayed
-
-
C2
Time
The time can be adjusted here
-
-
C3
Date
The date can be adjusted here
-
-
C4
Day
The day can be adjusted here
-
Monday
C5
Language
More languages can be selected here
-
English
C6
Contrast
The brightness of the screen can be adjusted here
0
– 10
5