Domestic Hot Water Heat Pump Service Manual
64
13.5 Replace the safety breakers
Tools:
BT20 Torx Screwdriver
, drill, rivet gun
1.
Complete step 13.1
Remove the
cables to the safety
breaker(s).
Using the drill:
gently drill the rivets
to remove the safety
breaker.
Note: the new safety
breakers must be
riveted back on to
the DHW-HP.
13.6 Replace the anode
Tools:
BT20 Torx Screwdriver
, 14mm socket, 34mm socket
1.
Complete step 13.1
Drain the tank so the
water level is below
the level of the
anode.
Remove the foam
insulation covering
the anode location
Using the 14mm
socket, remove nut
retaining the
grounding cable.
Using the 34mm
socket remove the
anode from the tank.