Domestic Hot Water Heat Pump Service Manual
67
13.10 Replace the BT2 sensor
Tools:
BT20 Torx Screwdriver
, terminal screwdriver
1.
Complete steps
13.1, 13.2 & 13.3
The BBT2 sensor
is located into the
heat exchanger at
the front of the
DHW-HP. The
sensor is placed into
the heat exchanger
11cm from the top,
7.5 cm from the
edge and 3cm in.
Remove the
cables from the
terminal block at the
top of the PC Board,
labelled BBT2.
The connection
block is a push fit
type, using the
terminal screwdriver
in the slot, push up
and pull the cable up
to remove.
13.11 Replace the BT3 sensor
Tools:
BT20 Torx Screwdriver
, terminal screwdriver
1.
Complete step 13.1
& 13.2
The BBT3 sensor
is located into the
top pocket to the
right of the electric
heating element.
The sensor is
inserted all the way
in until it stops.
Remove the
cables from the
terminal block at the
top of the PC Board,
labelled BBT3.
The connection
block is a push fit
type, using the
terminal screwdriver
in the slot, push up
and pull the cable up
to remove.