Hardware Diagnostics
HW Diagnostics Program Main Menu
127
- 01. NPX test checks the Addition and Multiplication functions of the coprocessor.
❖
08. CACHE MEMORY TEST tests the L2 caching unit.
CACHE MEMORY TEST (CAH) Error Log
❖
09. SCSI TEST checks the SCSI devices.
- 01. INQUIRY subtest issues the INQUIRY command to the SCSI bus and displays
result messages returned from the devices on the SCSI bus. After specifying the
valid host and channel number, the INQUIRY command is sent to the target SCSI
bus. It then displays the result code from ID0 through ID15.
The types of SCSI devices to be displayed are as follows:
The following screen provides an example of when the built-in CD-ROM drive is
connected to the on-board SCSI controller and the built-in hard disk drives are connected
to the MegaRAID Adapter.
Status
Error name
Meaning
01
MEMORY PARITY ERROR
Memory parity error
02
PROTECT MODE ERROR
Shift to the protected mode failed
03
CACHING ERROR
Error occurred on the cache
system
FF
DATA COMPARE ERROR
Data comparing error
07
EXCEPTION ERROR
Exception error
Type
Name
Type
Name
HDD
Hard Disk Drive
CD
CD-ROM Device
CMT
Magnetic Tape Device
SCN
Scanner
PRT
Printer
MO
Magnet-optic Disk Device
PRC
Processor (SAF-TE)
MC
Media Changer
WON
Write Once Device
COM
Communication Device
???
Undefined Device - Not
connected