Hardware Diagnostics
HW Diagnostics Program Main Menu
125
❖
06. SCSI HDD TEST checks the HDD functions connected to the SCSI-Bus through
ASPI driver software. Before starting the test, select the following parameters.
- 01. Sequential address read subtest is a sequential reading of all the blocks on the
HDD starting at block 0.
- 02. Connection subtest reads the logical sector at the end of the HDD and then
recognizes if the drive is connected or not.
SCSI HDD TEST (HDD) Error Log
Parameter
Meaning
HOST ID NUMBER
Sets the target host adapter number. When you
choose "ALL", the subtest tests all disks connected
to the server, and the next options, SCSI ID and
CHANNEL number will be ignored.
SCSI ID NUMBER
Sets the SCSI ID to test. You can specify just one ID
to test except ID:7.
CHANNEL NUMBER
If the server has multiple SCSI channels, this option
sets the channel number to test.
NOTE: The 01. SEQUENTIAL ADDRESS READ tests all area of the hard disk
drive. Depending on the capacity of the installed hard disk drives, the test may take
a few hours.
If you do not know where the hard disk drives are connected (host ID, SCSI ID and
channel number of the SCSI controller), you can find them 01. INQUIRY of 09.
SCSI TEST.
Status
Error name
Meaning
01
CHECK CONDITION OR BAD
COMAND
Bad command error
03
DRIVE SELECTION FAILED
Drive selection error
04
TARGET DRIVE BUSY
Target drive is busy
05
SCSI BUS TIME OUT
Time out error of SCSI bus
09
DMA BOUNDARY ERROR
DMA BOUNDARY occurred
0D
COMMAND TERMINATED
Command terminated
0E
QUEUE FULL
Command queue is full
80
NO SENSE
Sense data is invalid
81
RECOVERD ERROR
Execution of the command has
correctly finished because of
recovery treatment.
82
NOT READY
Condition does not satisfy for the
command execution
Содержание 3200
Страница 1: ... ...
Страница 309: ...309 ...