Micro-Master Touch User Guide
66
© 2014 Toro Australia Pty Ltd
Ver 1.2, June 2014
Flow Meter Delay
When a pump set is running it will periodically check an allocated Flow Meter. Depending on the
hydraulics of the irrigation system and the pump set capabilities a delay may be required to allow the
system to stabilise before automatically adjusting the pumps for the measured flow. This delay can
be set in this setting.
11.2
Pump Set List
The Pump Set List screen is displayed by pressing the
icon on the Home Screen.
Figure 43 - Pump Set List
Pump Set Names and Status
Each line in this list displays the name of the Pump Set (if assigned) and the current status of the
Pump Set. Clicking on a name will select the Pump Set, changing the background of the selected
Pump Set to light blue. Selecting a Pump Set and then clicking Edit will display the Pump Set Edit
screen.
Pump Set Status Icons
The status of each Pump Set is shown graphically using different icons.
Indicates a Pump Set is empty or is disabled. An empty Pump Set displays "**
Empty **", a disabled Pump Set displays the name of the Pump Set.
Indicates a Pump Set is not operating.
Indicates a Pump Set is operating.