Micro-Master Touch User Guide
25
© 2014 Toro Australia Pty Ltd
Ver 1.2, June 2014
between each key press. If you take longer than 5 seconds between each key the command
sequence will abort and no change will be effected. Once entered correctly the module will flash the
ON LED 3 times.
Setting the Unit Number and Expansion Module Slot Number
The RMT Field Module is capable of being a member of the Master Unit (Expansion Modules 2-4) or
any Remote Unit ( Expansion Modules 1 to 4). Use the guide below to set the relevant unit and
module ID.
To join the Master Unit press, SET, UNIT, SET. ie. press SET followed by UNIT(1) followed by SET.
The ON LED will flash 3 times.
To be part of Remote Unit 1 press, SET, UNIT, 1.
To be part of Remote Unit 2 press, SET, UNIT, 2.
To be part of Remote Unit 3 press, SET, UNIT, 3.
To be part of Remote Unit 4 press, SET, UNIT, 4.
Then select the Expansion Module position this module is to occupy by pressing, SET, MODULE,
followed by 1, 2, 3, or 4. The ON LED will flash 3 times.
Remember only 2 to 4 is valid for the Master Unit and ensure the module position is vacant, as a
RMT Field Module will take priority over an installed expansion module.
Setting PosiSense
The RMT Field Module is capable of supporting non-PosiSense and PosiSense solenoids in any mix
across the valve positions. Setting PosiSense is achieved in a similar manner as described above.
The ON LED will flash 3 times on a successful command.
For example, pressing SET, PosiSense, BERMAD, 2 will set output 2 as a Bermad solenoid.
Pressing SET, PosiSense, BACCARA, 7 will set output 7 as a Baccara solenoid.
Pressing SET, PosiSense, OFF, 1 will turn off PosiSense on output 1. PosiSense should be turned
off if an RM401 Pump Start Relay is connected to the output.
Any option selected without an output number at the end will have the effect of a blanket change on
all outputs.
For example, pressing SET, PosiSense, BERMAD (with no number keyed for 5 seconds), will set all
outputs for a Bermad solenoid.
Pressing SET, PosiSense, OFF (with no number keyed for 5 seconds) wil turn PosiSense OFF for all
outputs.
LED Indicators
The RMT Field Module has 5 LED lights across the right hand top of the keyboard panel. These are
marked as ON, OFF, PWR, RX & TX and behave as follows:
ON – flashes when a valve is turned on by pressing a valve key on the keyboard.
It is also used to show the valid entry of a setup command via the keyboard.
OFF – flashes when a valve is turned off by pressing a valve key on the keyboard.
PWR – Shows power to the module and the state of the radio connection. A solid ON or OFF
indicates a power issue, or a radio issue with the radio being unable to join the radio network. A