Fault Table (continued)
Fault
Number
Fault Title
Controller
Affected
Fault Condition/Circuit
Description
Additional
Notes
Service Actions
15
Software
Error
Primary
The software has detected
an issue with reading the
throttle sensor.
1.
Try rebooting machine,
disconnect and reconnect
the battery, look for short circuits
in the harness.
2.
Replace the TEC.
16
Contactor
Fault
Primary
The bus voltage was
high enough at power up
to require a discharge
before precharge. The bus
failed to discharge below
threshold in the required
amount of time.
At shutdown, the contactor
opens and the bus
discharges before shutting
the machine down. This
discharge failed to go
below the threshold in the
required amount of time.
Most likely cause is a shorted
contactor.
17
Throttle
Sensor
Fault
Primary
The sensor signals are
outside the expected
range.
Traction is
disabled.
1.
Test the throttle sensor.
2.
Test the throttle sensor circuit
wiring and connector P05.
3.
Replace throttle sensor.
18
Traction
Bail Sensor
Fault
Primary
The sensor signals are
outside the expected
range.
Traction is
disabled.
1.
Test the traction bail sensor.
2.
Test the traction bail sensor
circuit wiring and connector
P26.
3.
Replace traction bail sensor.
Greensmaster
®
eFlex 1021
Page 3–7
Troubleshooting: Machine Faults
20248SL Rev C
Содержание 04861
Страница 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Страница 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Страница 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Страница 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Страница 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Страница 48: ...Troubleshooting Grooming Reel Mechanical Problems Page 3 14 Greensmaster eFlex 1021 20248SL Rev C...
Страница 84: ...Traction and Reel Drive Systems Service and Repairs Page 4 36 Greensmaster eFlex 1021 20248SL Rev C...
Страница 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Страница 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Страница 231: ...Greensmaster eFlex 1021 Drawing 122 1647 Rev A Sheet 1 of 1 20248SL Rev C Page A 3 Electrical Schematic g349607...
Страница 232: ...Page A 4 20248SL Rev C Greensmaster eFlex 1021 Drawing 122 1734 Rev D Sheet 1 of 2 Wire Harness Drawing CV g349608...
Страница 233: ...Greensmaster eFlex 1021 Drawing 122 1734 Rev D Sheet 2 of 2 20248SL Rev C Page A 5 Wire Harness Drawing g349609...
Страница 234: ......