Testing the Main Contactor (continued)
g202780
Figure 63
1.
Main contact post
2.
Coil post
4. Record the wire connector locations on the contactor being tested for
assembly purposes, and disconnect the harness electrical connectors from
contactor. Check the contactor and the harness connectors for damage or
corrosion and clean or repair as necessary.
Note:
Prior to taking small resistance readings with a digital multimeter, short
the meter test leads together. The meter will display a small resistance value
(usually 0.5 ohms or less). This resistance is due to the internal resistance of
the meter and test leads. Subtract this value from the measured value for
the tested component.
5. Measure the resistance across the contactor coil terminals. Resistance of
the coil should be approximately 195 ohms.
6. With the contactor coil not energized, resistance across the contactor main
terminals should be infinite ohms.
7. If testing determines that the main contactor is damaged, ensure that the
battery pack is disconnected and then replace the main contactor.
8. After you complete the main contactor testing, install the battery cover onto
the battery mount. Secure the battery cover with four bolts.
9. Connect the battery pack; refer to
Disconnecting and Connecting the Lithium
Battery Pack (page 5–3)
.
Greensmaster
®
eFlex 1021
Page 5–37
Electrical System: Testing the Electrical Components
20248SL Rev C
Содержание 04861
Страница 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Страница 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Страница 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Страница 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Страница 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Страница 48: ...Troubleshooting Grooming Reel Mechanical Problems Page 3 14 Greensmaster eFlex 1021 20248SL Rev C...
Страница 84: ...Traction and Reel Drive Systems Service and Repairs Page 4 36 Greensmaster eFlex 1021 20248SL Rev C...
Страница 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Страница 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Страница 231: ...Greensmaster eFlex 1021 Drawing 122 1647 Rev A Sheet 1 of 1 20248SL Rev C Page A 3 Electrical Schematic g349607...
Страница 232: ...Page A 4 20248SL Rev C Greensmaster eFlex 1021 Drawing 122 1734 Rev D Sheet 1 of 2 Wire Harness Drawing CV g349608...
Страница 233: ...Greensmaster eFlex 1021 Drawing 122 1734 Rev D Sheet 2 of 2 20248SL Rev C Page A 5 Wire Harness Drawing g349609...
Страница 234: ......