7.4 PROGRAMMING
The electronic board contains two Programming menus: Basic and
Advanced.
L
i
In order to save the modifications made to the functions, scroll through
the menu until reaching gate status (
St
). If the mains power supply fails
before the modifications are saved, all the modifications will be lost.
To reset the default values for all the functions, open the EDGE contact
(EDGE SAFE LED off) and press the +, - and F buttons simultaneously
for 5 seconds.
BASIC PROGRAMMING
1. To access the menu, press and hold down button F: the display
shows the first function (
LO
).
L
i
The display continues to show the name of the function as long as
button F remains pressed.
2. Release button F: the display shows the value of the function.
3. Press the + or - buttons to modify the value of the function.
4. Press and hold down button F to go to the next function.
ADVANCED PROGRAMMING
1. To access the menu, press and hold down button F and then press
the + button: the display shows the first function (
bO
).
2. Release the + button whilst keeping button F pressed.
L
i
The display continues to show the name of the function as long as
button F remains pressed.
3. Release button F: the display shows the value of the function.
4. Press the + or - buttons to modify the value of the function.
5. Press and hold down button F to go to the next function.
1 4
Basic Programming
BASIC PROGRAMMING
Default
LO
Operating logics (§ ):
A
= Automatic
AP
= Automatic Step-by-Step
S
= Automatic “Safety”
E
= Semi-automatic
EP
= Semi-automatic Step-by-Step
C
= Dead Man
b
= Semi-automatic “B”
bC
= Mixed (
b
during opening /
C
during closing).
EP
PA
Pause time:
This has an effect only if an automatic logic has been selected. Ad-
justable from
0
to
59
, in 1 second steps. The display subsequently
changes to minutes and tens of seconds, separated by a point, in
10 second steps up to a maximum of
4.1
minutes.
E.g.
2.5
=2 min. and 50 sec.
2.0
FO
Force:
Regulates the thrust of the gear motor.
01
= Minimum power
50
= Maximum power
20
dI
Opening direction:
Indicates the gate opening movement, using the body of the gear
motor as a reference point (§ ).
-3
= Opening movement towards the right
E-
= Opening movement towards the left
-3
St
Gate status:
Exit from programming function and view status.
00
= Closed
01
= When opening
02
= Stopped
03
= Open
04
= Open in pause
05
= Fail-safe Test failed (§ -
, § )
06
= When closing
07
= When reversing
08
= Photocells tripped
1 5
Advanced Programming
ADVANCED PROGRAMMING
Default
bO
Maximum torque at initial thrust:
If active, the motor operates at maximum power as soon as move-
ment starts and ignores the
FO
function. This is useful with heavy
sliding gate sections.
Y
= Active
no
= Disabled
Y
br
Final braking:
If active, it sets a braking stroke to ensure that the gate stops imme-
diately when the gate engages the opening or closing limit switch.
If decelerations have been set, braking starts when they end.
00
= Braking disabled.
The braking time can be adjusted from
01
to
20
, in 0.1 second steps.
E.g.
10
=1 second.
05
Содержание POWERSLIDE
Страница 1: ...POWERSLIDE GEBRAUCHSANLEITUNG D 913002 26 6 50 01 2018...
Страница 2: ......
Страница 31: ...POWERSLIDE INSTRUCTION MANUAL GB...
Страница 32: ......
Страница 61: ...POWERSLIDE GEBRUIKSAANWIJZING NL...
Страница 62: ......
Страница 91: ...PowerSlide 31...