TopCold Romeo Скачать руководство пользователя страница 5

 28 

8.
Anomalies

GENERAL TROUBLESHOOTING LIST 

Failure 

Possible Reason 

What to do 

The device is not working, does not 
start.

 

No power to unit 

Check if plug is properly wired. 
Check if plug is ground and neutral 
wired. 
Check if any circuit breaker is down in 
the electrical box. 

Not cooling

 

Condenser blocked. 
Evaporators blocked. 
Air flow in the condenser obstructed. 

It often happens that all the refrigera-
tion components are working and still 
don’t cool. 
Check : 

The condenser

 – make sure it is clean 

otherwise clean it. 
Remove all the objects that may pre-
vent the good air flow into the conden-
ser. 

The evaporators -

 check evaporators 

for ice or blocked with products that 
may prevent the air flow. 
If they are blocked press dF button and 
wait until the ice is completely re-
moved even if you need to repeat this 
operation. 
Remove all the objects that may pre-
vent the good airflow into the evapora-
tors. 
As general advice: avoid direct sunlight 
or heat sources that can affect on the 
device like heaters, projectors, ventila-
tors or air conditioning equipment and/
or ventilation that has direct effect on 
the refrigerated equipment. 

Compressor broke down

 

Compressor “burns” for: 
Too many starts. 
Lack of refrigerant. 
Power supply failure. 
Filter obstructed. 
Condenser obstructed. 

If the compressor is “burnt”, the techni-
cian who will replace it has to consider: 
Refrigerant recovery if still existing. 
Do not pour the oil of the replaced 
compressor. 
To be quick in the replacement so that 
the oil of the new compressor is not in 
contact a too long time with the air as 
this later is highly hygroscope (capacity 
of absorbing water). 
Once the circuit is sealed, make a good 
vacuum and recharge the quantity of 
refrigerant. 
Filters should be also replaced as these 
have the property of retaining undesira-
ble particles in the installation and also 
humidity. 
The compressor should be replaced by 
one with identical features. 

Refrigerant leaking

 

Charging valve unscrewed. 
Poor use solder. 
Incomplete welding. 
Broken tubes. 
Attempted defrosting with pointed 
objects. 

Check if the device is working. 
If the condenser is not obstructed. 
If the condenser is not obstructed and if 
the fans are working switch of the de-
vices as it looks like a leak refrigerant. 
Call engineer to detect the leak, to elim-
inate it and change the filters – make 
the vacuum and replace the refrigerant 
quantity. 

 5 

SECURITY

 

a) The personnel responsible for the moving and instillation of the equipment

must have gloves, which should be flexible and anti-sliding, have protective 

glasses as well as protecting shoes. 

b) Protection equipment must always be used when necessary.

c)

In general the best practices for safety in work and hygiene should be applied

when working. 

d) To clean, the equipment should always be unplugged.

e) Never use sharp objects when cleaning the equipment.

1.
Basic 

C

a

re

 S

e

curit

y

Содержание Romeo

Страница 1: ...or safe and correct use of the equipment be sure to read the Safety Information in this manual before using it Manual Manual MAINTENANCE COMMANDS RECYCLING ANOMALIES UNPACKING ASSEMBLY PROCESURES OPERATION BASIC SECURITY PRECAUTIONS ...

Страница 2: ...2 31 ...

Страница 3: ...our Customer Service Department at 351 255 490 541 IMPORTANT INFORMATION PLEASE READ Please read these instructions carefully before installing or using If recommended procedure are not followed warranty claims will be denied Frilixa reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions ...

Страница 4: ...vice away from walls Controller failed Probe unwired from the terminals Probe with cut wire Probe with humidity See if there is any message error on the dis play Check that switches are well connected if so call the technician to check for the possible failure Controller burnt Power excess Starts exceed Water in the circuit Replace the controller and check the origin of the failure Controller with...

Страница 5: ...replace it has to consider Refrigerant recovery if still existing Do not pour the oil of the replaced compressor To be quick in the replacement so that the oil of the new compressor is not in contact a too long time with the air as this later is highly hygroscope capacity of absorbing water Once the circuit is sealed make a good vacuum and recharge the quantity of refrigerant Filters should be als...

Страница 6: ...le damages to the equipment caused by moving objects such as trolleys cleaning machines forklifts and other equipment 4 Clean the interior and exterior of the cabinet with a smooth cloth and warm wa ter with neutral soap 5 of the water volume Avoid that is gets splashed by the cleaning products used to wash the establish ment The substances used in cleaning of the floors can attack chemically the ...

Страница 7: ...binet will be installed is according to what is indicated on the identification plate The connection must have a ground wire element that besides being necessary is demanded by law The appliance is not equipped with electric protection devices against overload so it is recommend to verify the electric safety level of the installation network where the cabinet will be installed Do not connect any o...

Страница 8: ...perature of the food products there placed Food products with temperature above the one recommend for the working of the equipment must not be placed inside the unit Do not leave the food products in boxes or pallets more than the necessary time to load the equip ment unit In the food display equipment food products must be removed during the night and placed in a Cold Room or similar equipment to...

Страница 9: ...dance with local electrical codes Ground wire separately shall be provided for all installations The properly connected equipment goes ensure proper operation Requirements for electrical feeding equipment are in the serial data plaque See Fig1 Fig1 Subtitles Recommended is a hotline properly protected size appropriate from the facility s main source of equipment To ensure the correct voltage to be...

Страница 10: ...emperatures food may be loaded For opti mum energy efficiency we recommend allowing a 1 1 2 clearance between the interior cabinet wall and product load Important Notices Do not spill water on the equipment or on electrical components Do not use pressure water jet or any type of metallic objects in order to remove impurities or dirt Do not use substances or materials that are abrasive or solvents ...

Страница 11: ... DOWN button respectively press SET to temporarily save the new value and display the parameter again repeat the procedure for any other parameters that need to be modified press the SET button for more than 3 s to permanently save the parameters and exit the parameter setting proce dure Setting the default parameters To reset the default parameters disconnect power from the instrument 11 4 Unpack...

Страница 12: ...eaching the end defrost set point check parameters dt dP and d4 check the efficiency of the defrost The message disappears when the next defrost ends correctly dF flashing defrost running this is not an alarm signal but rather a message that the instrument is running a defrost Only shown if d6 0 cht flashing dirty condenser pre alarm check parameters A4 Ac AE and Acd CHt flashing dirty condenser a...

Страница 13: ... least once a month The accumulation of ice in the evapora tor reduces the performance and makes the energy costs rise Never remove the ice from the evaporator with metal objects such as knifes or cutting objects When the evaporator has ice the ideal is to let it defrost naturally of the evaporator Water resulting from daily defrosting is collected in a plastic recipient that must be emptied whene...

Страница 14: ...els with 3 inputs and with multifunction input configured as a probe and after 1 s the temperature measured by the selected probe will be displayed To display the other probes press DOWN again To return to the normal display wait 3 s without pressing any buttons exit by timeout TABLES OF ALARMS AND PARAMETERS Table of alarms and signals When an alarm is activated the display shows the correspondin...

Страница 15: ...press SET for 1 s the set value will start flashing increase or decrease the value using UP or DOWN press SET to confirm the new value Important the PJEZM models fitted with keypad simply monitor the deviation from the set point and where neces sary signal na alarm On these models the set point can only be modified using parameter St Manual defrost Not available on the easy and easy compact thermo...

Страница 16: ...eted simply power up the controller to make it operative CAREL then recommends to check that the display does not show any alarm signals then set the time and date and finally set the parameters as desired The main parameters are as follows SC1 PROBE PS PASSWORD Functions available from the keypad ...

Отзывы: