Install the unit on a flat, clean area away from sources of heat, always in places
where there is fresh water projection;
Plug the appliance into a mains socket with earth contact;
Periodically check the condition of the power cord of the appliance and the wall
socket of your installation. In case they are damaged, call for assistance;
Before starting any maintenance operation and equipment cleaning disconnect
the unit from the mains by removing the plug from the socket;
To make changing bulbs, unplug the appliance by removing the plug from the
socket.
Do not overload the equipment. Please meet the load limit, when applied.
One must not store explosive substances such as aerosols containing flammable
gas propellants;
The models were designed for operation under conditions of bold.
29
Water on floor
Bad leveled.
Evaporation system failed.
If some water appears on the floor, see if the
equipment is leveled.
Check if the automatic system of evaporation
of waters is working properly or drain waters
system is not blocked.
Some condensate waters can be released on
the walls because of bad circulation of steam
so keep the device away from walls.
Controller failed
Probe unwired from the terminals.
Probe with cut wire.
Probe with humidity.
See if there is any message error on the dis-
play.
Check that switches are well connected; if so
call the technician to check for the possible
failure.
Controller “burnt”
Power excess.
Starts exceed.
Water in the circuit.
Replace the controller and check the origin of
the failure.
Controller with unsettled parameters
Operating by unskilled people.
Call the technician to reprogram the controller
parameters.
Condenser fans failed
Failure by obstruction.
Replace fans.
Check the source of failure.
Evaporator fans failed
Water inside the circuit.
Failure by obstruction.
Replace the fans.
Check the source of failure.
Lights failed
Starter or tube failure
If the tubes don’t light check them or starters.
When you replace the tube and if this is still
failing then replace the ballast.
It may come from the oxidation of the termi-
nals because of the humid ambient of these
devices
.
Condensate water evaporation system
Heater burnt.
According to the system you are using, if your
equipment makes the power supply down or
circuit breaker down, it is possible that one of
the components has ground wired and it may
be the heater burnt.
Note: these operations should be carried out
by skilled people and when heaters are diving
in water.