e
1.
Remove panel on the front side by lifting it up with a screwdriver.
2.
Slide the side panels backwards and remove these panels.
3.
Loosen the screws from the back panel and lift this panel out.
4.
Reverse the procedure to install.
INSTALLING SHELVES
1.
For removing the shelves is only neces-
sary to push forward.
2.
Reverse the procedure to install.
PANELS BOTTOM SIDE
21
check parameters AH, Ad and A0.
The alarm is automatically reset when the temperature returns within the set limits (see parameter AH).
EE displayed during operation or on power-up
unit parameter reading error. See Data errors.
EF displayed during operation or on power-up
operating parameter reading error. See Data errors.
Ed flashing
The last defrost ended after exceeding the maximum duration rather than when reaching the end defrost set
point.
check parameters dt, dP and d4;
check the efficiency of the defrost.
The message disappears when the next defrost ends correctly.
dF flashing
defrost running:
this is not an alarm signal, but rather a message that the instrument is running a defrost. Only shown if
d6= 0.
cht flashing
dirty condenser pre-alarm:
check parameters A4, Ac, AE and Acd.
CHt flashing
dirty condenser alarm:
check parameters A4, Ac, AE and Acd.
EtC flashing
internal clock error.
Data error
In certain operating conditions, the instrument may detect errors in the data saved. These errors may compromise the
correct operation of the instrument. If the microprocessor detects a data saving error, the display shows the message
“EE”. If the fault persists, the controller needs to be replaced. If, on the other hand, the message disappears, it can con-
tinue to be used. When “EE” error occurs frequently and/or remains for some time, the controller should be checked,
as the original precision may not be guaranteed.