Mobile service stations
EN
12
Connection to the pneumatic supply
Please note: use filtered and dry air only.
- Verify that the supply faucet of the suction cleaner is closed.
- Connect the supply faucet to a pipe with an internal diameter of 8 mm.
- Adjust the supply pressure at 7 bar.
- Connect the pneumatic tool to the fitting on the sleeve and the suction pipe to the socket on the pneumatic tool.
WARNING: for a correct operation, the suction cleaner requires an amount of air equivalent to 1000l/min, added to
the amount of air required by the connected pneumatic tool. Verify that the compressed air plant is able to supply the
required amount to the machine.
Connection to the grounding system
CAUTION: ALWAYS connect the machine to the grounding system of the plant using the metal pliers, spe-
cifically during the use of the suction cleaner, the emptying of the dust bag and its replacement.
Connect the metal pliers to a part of the area that is connected to the grounding system of the plant. (see
figure 5)
USER MANUAL
Operation
The supply of the pneumatic tool and suction cleaner can be controlled by means of the faucet situated on the rear of
the suction cleaner.
To protect operators, the pneumatic tool should always be started together with the suction cleaner to avoid the dust
produced from forming potentially explosive atmospheres.
Verify that the suction sleeve is correctly connected to the pneumatic tool and suction pipe union. Always check the
conditions of the dust suction sleeve before using the machine.
Turn the faucet to start the vacuum cleaner. Switch the pneumatic tool on to start working.
At the end of the work, stop the tool, close the faucet to stop the vacuum cleaner and place the tool on the support
provided.
Use the side supports to wind the supply pipe and the suction sleeve at the end of the work. Place the abrasives, work
tools, etc. on the rear shelf.
Before moving the suction cleaner within the working area, make sure that the front breaks are disconnected and that
the metal pliers are not connected to fixed parts of the working area.
N.B.: the machine generally outputs air at low speed during operation.
Potential problems
If dust is ejected from the suction cleaner, immediately close the supply faucet. Verify that the faucet, head and filter
are correctly fitted and the connections are firm. If leaks occur on the compressed air pipes, close the supply faucet.
In the event of doubt or if you are unable to identify the leak, contact an authorized JBDC representative.
ROUTINE MAINTENANCE MANUAL
Emptying the dust bin
WARNING: this operation may lead to the formation of potentially explosive atmospheres and deposits. Avoid using
potential sources of ignition next to the machine, for example: mechanical sparks, electric parts, hot surfaces, flames,
hot gases and electrostatic charges. In the event of explosive atmospheres, always follow internal safety instruction and
procedures as indicated by the Atex 2014/34/UE Directive.
Verify that the dust bag inside the drum has been filled at the end of each working day.
The dust bag has a maximum capacity of 7kg and a volume of 20 l, which should never be exceeded.
If the removed bag is damaged, use utmost care following the internal safety instructions and procedures applicable to
explosive atmospheres indicated in the Atex 2014/34/UE Directive.
NEVER reuse the dust bag and use ONLY JBDC dust bags (ref. 058880). Store the spare bags in a dry area.
Bags should be disposed in accordance with law requirements and internal safety regulations applicable to the handling
of potentially explosive dusts.
Always verify that the metal pliers are connected to the grounding system of the plant before performing this operation.
Close the compressed air supply faucet on the rear of the suction cleaner.
Disconnect the supply quick fitting from the suction cleaner before removing the latter.
Remove the locking metal hooks and carefully lift the suction cleaner head with the handle provided.
Rest the head on the worktop.
Loosen the flange of the dust bag from the suction pipe union, then close the dust bag with the cap to prevent dust
from leaking during transport.
Carefully lift the dust bag and place it in a dedicated area within the plant. Remove dust residuals from inside the bin.