9
general DeSCription
HELIX
2.3
elecTrIcAl / geNerATor requIremeNTS
i
It is recommended that the Helix System be used
with a generator. This provides the flexibility
with not having to use the public power grid.
When connected to the public, low-voltage
network, it is possible that an approval of
the network operator is required. Check the
regulations in your country and contact your
network operator before connecting the unit to
a public electricity grid.
i
The Helix System requires a 208-240V capacity.
Make sure the power source is rated to this
specification.
i
When working at altitudes above 2100m, check
the generator manufacturer’s specifications for
power loss offset.
Attention
If powering the Helix system with a generator,
make sure the generator has ample power to
run the system. An inadequate generator will
cause RPM fluctuations in the Component Pump
motors during usage and can cause damage.
Follow the steps below to determing if your generator is able to
supply sufficient power to the Helix system.
1. Perform this equation:
System Watts 13,300 x 1.25 = kVA (kilovolt / amperes)
2. If your generator’s kVA rating is higher than what was
determined in the equation above, the generator will be
able to power the system.
If your generator’s kVA rating is lower than what was
determined in the equation above, the generator WILL
NOT be able to power the system. A larger generator is
required.