ADVANCED
Contains advanced option that normally do not need to be edited after installation.
POWER STATE - Set if the X300 will RECORD AT POWER UP, DO NOT RECORD or USE LAST
STATE. If use last state is selected the unit will record on power up if it was recording when power was
disconnected. If it was not recording when power was disconnected, it will return to this state on power
up. Default setting is RECORD AT POWER UP.
ENABLE RECORD BUTTON controls whether the record button on the front panel can be used to start
and stop recording (enable/disable).
LIVE VIEW - if set to YES, live view of camera will be displayed even if the disk cartridge is removed. If
set to NO and the cartridge is not present, the initialisation screen is shown.
SPLASH SCREEN controls the length of time an operator logo will be displayed. A .bmp file can be
loaded / displayed on boot up. The .bmp must be in a specific format and copied onto the cartridge. See
APPENDIX 2
– Splash Screen for further details.
HEALTH PAGE DISPLAY controls the length of time the unit health status will be displayed for on boot
up. The health page includes a simple traffic light status and may include service/fail code conditions as
well as the current recording state. The health page can also be activated via an alarm input.