36
Genie Distribution User Manual v1.6
© Tieline Pty. Ltd. 2015
pins 4 and 5 at the last socket on the ISDN line. Check your NT-1 device user manual as
this may be supported. Suppliers of electronic components sell suitable plugs with
termination resistors when required. Please note: U interface ISDN terminations do not
require terminating resistors.
How to Configure ISDN G5 Modules
To configure the codec to dial using ISDN for the first time:
1. Ensure that the correct country setting is configured in your codec via
Settings > System >
Country
.
2. If you are dialing between two Tieline codecs you normally only need to
configure an ISDN
dialing program
via
Connect > ISDN
. See
Configuring ISDN
to adjust settings using the Java
Toolbox Web-GUI, or click
here
to adjust settings using the HTML5 Toolbox Web-GUI.
Other more advanced settings can also be configured:
1. Select
Settings > Modules > [Select ISDN Module]
to adjust ISDN module settings
specific to your codec site. See
Configure ISDN Module Settings
for more information. See
Configuring ISDN Modules
to adjust settings using the Java Toolbox Web-GUI, or click
here
to adjust settings using the HTML5 Toolbox Web-GUI.
2. ISDN answering can be configured to suit:
·
Hardware available in the codec, i.e. the number of B channels available.
·
Expected dialing behaviors, e.g. if B channels should bond or not, and whether audio
streams need to use
Route
tags.
·
The type of call being made, e.g. Tieline (with Tieline Session Data) versus non-Tieline
(sessionless calls).
Adjust answering configuration via
Settings > Answering > ISDN Answer Configs > [Select
Config]
and see
ISDN Answering Configuration
for more information (see
Configuring ISDN
Answering
to adjust settings using the Java Toolbox Web-GUI, or click
here
to adjust settings
using the HTML5 Toolbox Web-GUI).
12.1
ISDN Module Settings
ISDN settings in the
Module
menu will determine how each installed module operates at a
particular site. This allows you to copy programs between codecs installed at different locations
and separately configure site-specific settings for how each ISDN module should connect. Other
answering-related settings are available in the
Answering
menu via
Settings > Answering >
[Select ISDN Config
].
Configuring ISDN G5 Modules
1. Press the the
SETTINGS
button, then navigate to
Modules
and press the
button.
Important Note:
You can also configure your ISDN module by pressing the
HOME
button
to return to the
Home
screen and select
Connect > ISDN
. Then use the down
navigation button to select
Module Configuration
and press the
button.