152
Genie Distribution User Manual v1.6
© Tieline Pty. Ltd. 2015
the answering codec.
Click the drop-down arrows on the right-hand side of each text box to adjust the
Encoding
,
Sample rate
or
Bit rate
options.
Click to configure:
·
Auto Jitter Adapt
and the preferred auto jitter setting using the drop-down arrow
for
Buffer priority
, or
·
Fixed Buffer Level
and enter the
Jitter Depth
, which must be between 12ms and
5000ms depending on the algorithm you select.
·
Local
and
Remote FEC
settings if required.
Click the check-box to select
Enable Redundant SmartStream PLUS
and configure
dual Ethernet SmartStream IP streaming. Alternatively, click
Next
to configure
Auto
Reconnect
or a backup connection, whereby the alternative connection is dialed if the
primary connection fails.
By default, primary IP streaming is via
ETH1
. To achieve the maximum level of
redundancy select
Secondary
to configure redundant streaming from the secondary IP
port
ETH2
. The redundant stream uses
Send Audio Port 9001
by default and the
Return
Audio
Port
allocated is
Automatic
. Note:
Automatic
indicates that the codec will
arbitrarily allocate the return port value and send this information to the codec to which
you are dialing.