When an auto-answer connection is established, an event is registered in the
Auto
Answer
dialog box, as shown below, and logged in the auto-answer log file (see
Auto-
answer Configuration
).
When a site has connected, it will remain connected for two minutes just as if connected
by the operator. During this time, the operator can view the controllers and determine the
cause of the alarm. The status bar will also display a countdown of the remaining
connection time in seconds.
5.
CIM Bypass Wiring
The CIM bypass connection mode of operation has a different wiring scheme than a standard
CIM connection. The two possible methods of connection are: direct--from computer to
controller and modem--from computer to local modem to remote modem to controller. The direct
connection bypass mode is shown below:
IBM Compatible
RS-232
to
RS-422
RS-232
RS-422
The modem connection bypass mode is shown below:
Modem
Modem
Computer
RS-232
to
RS-422
RS-232
NULL
RS-422