ANNEX D - CARD REQUIRED TO PUT THE MACHINE INTO OPERATION
MACHINE DATA CHART
Heating inc. degrs./10ms [ Def . 010 ]
( 1.XXX ) :
1.
KV Gain
[ Def . 200 ]
( 2.XXX ) :
2.
KINT Gain
[ Def . 50.0 ]
( 3.XXX ) :
3.
KINT operating threshold [ Def . 060 ]
( 4.XXX ) :
4.
00C = °C / 00F = ° F
[ Def . 00C ]
( 5.XXX ) :
5.
50 / 60 Hz
[ AUTOM. ]
( 6.XXX ) :
6.
Max. sealing time
[ Def . 4.0 ]
( 7.XXX ) :
7.
Partial short circuit factor [ Def . 01.2 ]
( 8.XXX ) :
8.
Fault display enable
[ Def . 255 ]
( 9.XXX ) :
9.
Rated I
[ Def . 30 / 60 ]
( A.XXX ) :
A.
KD Gain
[ Def . 010 ]
( B.XXX ) :
B.
1 = cold system compen. [ Def . 000 ]
( C.XXX ) :
C.
1 = AB Serial printer [ Def . 0 ] ( D.XXX ) : D.
Sealer no. for printer [ Def . 0 ] ( E.XXX ) : E.
Enable energy [Def. 1 ] ( F.XXX ) : F.
Current tol. during pre-heat [Def 4.0] ( H.XXX) : H.
Phase tol. during pre-heat [Def. 6.0] ( I.XXX ) : I.
Curr. tol. during sealing [Def. 4.0] ( L.XXX ) : L.
Phase tol. during sealing [Def. 6.0] ( O.XXX ) : O.
Min. limit for energy input [Def. 60 ] ( P.XXX ) : P.