Pag. 14
Tot 27.
THERMOSALD UPSCR_M_V3
08/2000
3.7
COLD SYSTEM COMPENSATION OPTION (enabled from machine data C.XXX )
3.8
GENERAL RESET PROCEDURE ( CONTACT THE SUPPLIER )
4 - MACHINE DATA
0XXX SETTING THE INITIAL SEALING TEMPERATURE WITH SYSTEM COLD - While the WELDING
Led on the panel is still flashing , press the RESET / MODE key. The display will show the set initial sealing
temperature with the machine cold. To change the temperature press the UP and DOWN keys.
If no operations are performed for 3 seconds, the board will automatically display the actual temperature. This option is
used to automatically bring the jaws and the sealing system to the correct operating temperature when the machine is
still cold.
This temperature is used when the board receives the sealing signal and the system temperature is lower than that set for
parameter SYSTEM OPERATING TEMPERATURE.
_XXX SYSTEM OPERATING TEMPERATURE. While the display is showing the INITIAL SEALING
TEMPERATURE WITH SYSTEM COLD, press the RESET / MODE key; the display shows the set operating
temperature of the system. To change the temperature, press the UP and DOWN keys.
If no operations are performed for 3 seconds, the board will automatically display the actual temperature.
•
This procedure is used at the beginning and at the end of machine testing by qualified personnel in order to reset the
system memory. The procedure can be repeated in particular cases following malfunctioning which causes the machine
to stop.
•
Contact the supplier to obtain the authorisation to perform this procedure
•
Turn off the equipment.
•
Keep the DOWN and RESET keys pressed until the equipment is turned back on again. Four blocks will appear on the
display.
•
Check the dip switches
•
Check balancing
•
Enter the heating factor (Parameter 5 appears, Set data with the system hot)
•
Check machine data
•
Perform the standard procedure in order to put the machine into operation.
Содержание UPSCR10030-M-V3