Electrical Maintenance
79
NOTE: The cylinder head cover must be
removed to access the glow plugs.
A shorted glow plug will show excessive current
draw (more than 13 amps) during preheat, and
may cause fuse F5 (40 A) to blow. Check each
glow plug individually.
Unit Wiring
Inspect the unit wiring and the wire harnesses
during scheduled maintenance inspections for
loose, chafed or broken wires to protect against
unit malfunctions due to open or short circuits.
AC Components (Model 50
Units Only)
Electrical Contactors
Test the contact points by checking the voltage
drop across each set of points when the contactor
is energized and the system is operating. If the
voltage drop across a set of points is more than
0.25 Vac, replace the contactor.
Test the contactor coil as follows:
1. Check the voltage to the coil. It should be at
battery (source) voltage. If not, check for an
open circuit.
2. Check the voltage after the coil. It should be 0
volts. If not, check for an open or high
resistance in the circuit to ground. If the
voltage is 0 but the contactor does not pull-in,
the coil is probably open. Ohm check to
verify.
Evaporator Heaters (Optional)
Test the resistance of each evaporator heater by
disconnecting it from the circuit and checking it
with an ohmmeter. The resistance of each
evaporator heater should be approximately
71 ohms.
Condenser Fan Rotation
The condenser fan is belt driven. On electric
standby operation, check for correct fan rotation
by placing a small cloth or sheet of paper against
the condenser fan grille on the front of the unit.
Correct rotation will hold the cloth or paper
against the grille. Improper rotation will blow the
cloth or paper away from the grille. To correct
incorrect rotation, check the motor and motor
contactor wiring per the unit wiring diagram.
Phase Select Module for Truck Unit
Model 50 Applications
The phase select module is designed to monitor
both single and 3 phase nominal input voltages
between 200 and 480 volts AC.
Operation
The phase select module will detect missing
phases, phase orientation and low voltage on three
phase or single phase power. The Brown, Gray,
and Black wires are used to sample the power at
CAUTION: Model 50 units use high
voltage ac for electric standby operation.
Lethal voltage potentials can exist on
connections in the high voltage box. Take
appropriate precautions and use extreme
care when testing the unit.
1.
MCB–Motor Contactor
2.
MCA–Motor Contactor
3.
Base Controller/Interface Board Assembly
4.
Overload Relay
5.
Phase Select Module
Figure 152: Model 50 Control Box Components
with High Voltage Cover Removed
1
2
3
4
5
Содержание T-1080S
Страница 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Страница 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Страница 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 186: ...185 Wiring Diagram Page 1 of 5 ...
Страница 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 188: ...187 Wiring Diagram Page 3 of 5 ...
Страница 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 190: ...189 Wiring Diagram Page 5 of 5 ...