Electrical Maintenance
83
4. Move the slide switch down until it clicks into
place at the bottom of the slot (from which the
tab marked “H” was removed). This sets the
overload relay to reset automatically.
The new overload relay is now set up correctly.
Note which wires go to which terminals when
removing the old overload relay so the wires are
connected correctly when the new overload relay
is installed.
1.
Switch Clicks into Place at Bottom of Slot
Figure 156: Move Switch Down