Operating Instructions for Premium HMI Control Panel
60
•
If the alarm does not reoccur during the timed
running interval with reduced performance,
the unit will return to full performance to
determine if continued operation is possible.
The unit will run in this manner for a timed
interval. If the unit is successfully able to
return to full performance for the timed
interval without the alarm re-occurring, the
alarm is auto cleared and the unit will run
normally.
•
All Prevent Alarm events and conditions are
logged by the ServiceWatch Data Logger.
•
In general, if the alarm condition re-occurs a
defined number of times, the alarm is set as a
shutdown alarm and no further restarts are
possible.
NOTE: If the Restart After Shutdown feature in
the Guarded Access Menu is set for
CONTINUOUS, then an unlimited number of
restart attempts are allowed.
Pretrip Alarm Codes
If an alarm occurs during a Pretrip Test the alarm
code will be displayed as Pretrip Alarm XX,
where XX is the alarm code.
Alarm Codes When Switching Between
Diesel and Electric
If a shutdown alarm occurs that affects only diesel
mode operation and the unit is switched to
electric, the diesel mode shutdown alarm becomes
an electric mode log alarm. This allows the unit to
run in electric mode without clearing the
shutdown alarm that is preventing diesel mode
operation. If the unit is switched back to diesel
mode, the alarm again become a diesel mode
shutdown alarm and prevents unit operation.
In the same manner, if a shutdown alarm occurs
that affects only electric mode operation and the
unit is switched to diesel, the electric mode
shutdown alarm becomes a diesel mode log alarm
to allow diesel mode operation. If the unit is
switched back to electric mode, the alarm reverts
to an electric mode shutdown alarm and prevents
unit operation. If the unit is configured for electric
to diesel autoswitch, it automatically starts and
runs in diesel mode if an electric shutdown
occurs.
Alarm Code Notification
The Alarm Icon used in previous Thermo King
controllers has been incorporated. If a Check
alarm condition occurs the Alarm Icon will appear
in the display as shown in Figure 92.
Figure 92: Alarm Icon
If a Shutdown Alarm occurs it will be indicated
by all of the following:
1. The Alarm Icon will appear.
2. The display and backlight will flash on and
off.
3. The display will switch from normal video to
reverse video and back to normal video.
(Light areas become dark and dark areas
become light.)
Clearing Alarm Codes
Most alarm codes can be cleared conventionally
from the Alarm Menu using the CLEAR key.
The following control and display sensor alarm
codes can only be cleared from the Maintenance
Menu or Guarded Access Menu:
•
Alarm Code 03 Check Control Return Air
Sensor
•
Alarm Code 04 Check Control Discharge Air
Sensor
The following alarm codes clear automatically.
•
Alarm Code 64 Pretrip Reminder - Clears
when a Pretrip Test is performed.
•
Alarm Code 84 Restart Null - Clears when the
unit is no longer in a restart null due to a
Prevent Alarm.
•
Alarm Code 85 Forced Unit Operation -
Clears when the unit is no longer running in a
forced mode due to a Prevent Alarm.
•
Alarm Code 91 Check Electric Ready Input -
Clears automatically when the unit starts
running.
Содержание T-1080S
Страница 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Страница 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Страница 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 186: ...185 Wiring Diagram Page 1 of 5 ...
Страница 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 188: ...187 Wiring Diagram Page 3 of 5 ...
Страница 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 190: ...189 Wiring Diagram Page 5 of 5 ...