9
Consideration to the surroundings
• Do not install the Water Heater where the
exhaust will blow on outer walls, other walls
or material not resistant to heat. Also consider
the surrounding trees and animals.
The heat and moisture from the Water
Heater may cause discoloration of walls and
resinous materials, or corrosion of aluminium
materials.
• Do not locate the vent termination directed
towards a window or any other structure
which has glass or wired glass facing the
termination.
• Take care that noise and exhaust gas will not
affect neighbors.
• On combustible surfaces
(e.g. weatherboards), it
is not required to install
a fire proof back board.
• Install in a location
where the exhaust gas
flow will not be affected
by fans or range hoods.
Install according to regulations and manual
• The Water Heater must be installed according
to manual.
• Before installing, make sure that the vent
termination will have the proper clearances
according to AS/NZS 5601, or your local
authority.
CAUTION
NOT
CORRECT
Do not install in the following places
• A location where it is not free from obstacles
and stagnant air.
• Near staircases or emergency exits.
CAUTION
• This Water Heater is for outdoor installation
only. Do not install indoors.
• Do not enclose the termination with
corrugated metal or other materials.
This will cause carbon monoxide poisoning
and a potential fire hazard.
DANGER
Locate the appliance in an area where water
leakage from the unit or connections will not
result in damage to the area adjacent to the
appliance or to the lower floors of the structure.
When such locations cannot be avoided, it
is recommended that a suitable drain pan,
adequately drained, be installed under the
appliance. The pan must not restrict combustion
air flow.
NOTICE
• Avoid places where fires are common, such as
those where petrol, benzene and adhesives
are handled, or places in which corrosive
gases (ammonia, chlorine, sulfur, ethylene
compounds, acids) are present.
If you do not follow the above, a fire or
explosion may result causing property
damage, personal injury or death.
• Avoid installation in places where dust or
debris will accumulate. Dust may block the
air-supply opening, causing the performance
of the device fan to drop and incomplete
combustion to occur as a result.
• Avoid installation in places where special
chemical agents (e.g. hair spray or spray
detergent) are used.
Ignition failures and malfunctions may occur
as a result.
• Do not install this Water Heater in a mobile
home, recreational vehicle or on a boat as this
may be a Carbon Monoxide Poisoning Hazard.
• Leave the proper clearance between the
Water Heater and nearby
objects (trees, timber,
boxes with
flammable
materials, etc.).
WARNING
3. Choosing an Installation Location
Upper:
Min. 500 mm
Right side:
Min.
500 mm
Left side:
Min.
500 mm
Front:
Sug. 600 mm
Содержание TH32END5L