19
Ground
To prevent electrical shock, always plug power lead
into an earthed point.
8.1 Water Heater
Electrical Shock Hazard
Do not connect the electrical power to the
appliance until all Remote Controllers have been
connected.
It may result in death or serious injury from
electrical shock.
WARNING
Electrostatic discharge can affect electronic
components.
Take precautions to prevent electrostatic
discharges from personnel or hand tools during
the Water Heater installation and servicing to
protect product’s electronic control.
CAUTION
Power Supply
• The Water Heater is equipped with a 1.5 m cable
with a three pinned earthed plug to be connected
to 230 - 240 VAC at 50 Hz.
The power consumption may be up to 246 W.
Use an appropriate circuit.
• The Water Heater requires 230-240 VAC 50 Hz in
Australia and New Zealand, weatherproof plug
installed in a protected position adjacent to the
appliance.
• If the power cord is damaged and requires
replacement, use only an original spare part
available from the manufacturer.
• Tie the redundant power cord outside the Water
Heater. Putting the redundant length of cord
inside the Water Heater may cause electrical
interference and faulty operation.
NOTE
• Do not let the power cord
contact the gas piping.
• Do not disconnect the electrical
power when not in use. When
the power is off, the freeze
prevention in the Water Heater
will not operate, resulting in
possible freezing damage.
8. Connecting Electricity
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
1.White
2.Green
3.Red
4.Black
5.Blue
6.Blue
A
B
Quick Connect
Cord
“Quick Connect
Cord” tag
• The wire coloring on the Quick Connect Cord
will not be the same as the wire coloring of the
connection plug inside the Water Heater.
8.2 Quick Connect Cord
NOTE
For Quick Connect Multi-System
installation only use the Quick
Connect Cord (part No. CF-
0706377, sold separately).
NOTE
Do not connect the Remote
Controller to both Water Heaters.
If the Remote Controller is
connected to both Water Heaters,
remove the unnecessary Remote
Controller before connecting the
Quick Connect Cord.
• The Remote Controller can be connected to
either Water Heater A or B only.
Содержание TH32END5L