Thermann Installer’s Manual
Gas Continuous Flow Water Heaters
6
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water
temperature.
Item
Maximum Performance
Gas Consumption
NG
250 MJ/hr
ULPG
250 MJ/hr
Maximum Hot Water Capacity (25°C Rise)
32 L/min
Performances
2.2 Specifications
Model Name
TH32END5(6)N
TH32END5(6)L
Type
Installation
Outdoor, Wall mounted
Air Supply / Exhaust
Power Flue
Operating Pressure
200 -1,000 kPa
Minimum Flow Rate
2.0 L/min
Dimensions (Height) × (Width) × (Depth)
615 mm × 464 mm × 240 mm
Weight
30 kg
Water Holding Capacity
1.2 L
Connection
Sizes
Water Inlet
R 3/4 (20 mm)
Hot Water Outlet
R 3/4 (20 mm)
Gas Inlet
R 3/4 (20 mm)
Power
Supply
Supply
230 - 240 VAC (50 Hz)
Consumption
NG/ULPG
76.0 W / 101.0 W
Freeze
Prevention
145 W
Burner Injector Size
NG
2.4 mm
ULPG
1.5 mm
Accessories
Anchoring Screws
Содержание TH32END5L
Страница 30: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 30 ...
Страница 31: ...31 ...
Страница 32: ......