21
9.1 Connecting Remote Controller Cord to the Water Heater
NOTE
• Tie the excess cord outside the
Water Heater. Do not put the
extra length inside the Water
Heater.
• The remote controller cord can
be extended up to 35 m.
• Be sure to hand tighten when
screwing to the terminal block.
Power tools may cause damage
to the terminal block.
TH32END series
Main Controller
Bath Room Controller
Operation
ECM1T
RC-9018C
ECB1T
ECB2T
General application
Works
Won't work
Won't work
Works
(× 2)
Works
(× 2)
Won't work
(× 2)
Won't work
Maximum number of installed
1
1
1
2-3
Total: 4
Quick Connect Multi-System (2 units)
Recirculation system
(55°C model only) (1 unit only)
Works
* The Remote Controller used is different, for general application (one unit installation) and piping applications
(Quick Connect Multi-System / Recirculation system).
• Use remote controller cord for any extensions.
• Install according to the National Electrical Code
and all applicable local codes.
1. Disconnect the electrical power to the Water
Heater.
2. Leave enough slack so that the remote
controller cord will not be damaged if the Water
Heater is removed from the wall.
3. Remove the front cover (4 screws).
4. Pass the remote controller cord through the
wiring throughway and into the Water Heater.
5. Connect the Y-shaped terminals at the end of
the remote controller cord to the terminal block.
6. Secure the remote controller cord with a clamp.
7. Reattach the front cover.
9. Remote Controller
Cord Clamp
Remote
Controller
Terminals