When changing the temperature, make sure to
confirm with the customer that the temperature
of the hot water will be very high and that there
is a risk of scalding.
WARNING
9.2 Temperature Setting
To ensure compliance with Australian Standard AS/
NZS 3500.4, for sanitary areas, install the Water
Heater with a tempering valve. In New Zealand,
please refer to the New Zealand Building Code
and all other applicable electrical, gas fitting and
plumbing codes.
Temperature is controlled by the maximum
temperature set in the Water Heater.
2. Remove the front cover (4 screws).
DISPLAY
MODE
button
UP
button
DOWN
button
MINIMUM
button
MAXIMUM
button
4. Reattach the front cover (4 screws).
4) After selecting the temperature, press MODE
button again for 2 seconds.
• If “---” is displayed for a few seconds, turn
the power off at the power point and wait
10 seconds, then turn the back on and
repeat steps 3 1) to 4).
[The changing procedure of the maximum
temperature setting]
1. Turn the Water Heater off by pressing the
Operation button on the Remote Controller.
NOTE
Do not use the Water Heater while
temperature setting.
NOTE
This setting (“F03”) must be done
with all hot water fixtures closed
within the first 10 minutes of
connecting the electrical power to
the Water Heater.
3. Change the temperature with MODE button and
UP/DOWN button on the status display.
1) Press and hold MODE button for 2 seconds,
and set the DISPLAY to “F03” using UP or
DOWN button.
2) Press MODE button once when DISPLAY
lights “F03”.
• Switch to SELECT mode.
3) Select the temperature using UP or DOWN
button.
50°C model: 37-48°C (In 1°C intervals), 50°C
55°C model: 37-48°C (In 1°C intervals), 50°C,
55°C, 60°C, 75°C