Thermann Installer’s Manual
Gas Continuous Flow Water Heaters
18
• Pipe and fittings must meet the installation
requirements of AS/NZS 3500.4.
• Hot water lines should be lagged with suitable
insulating material.
• DO NOT FIT ANY VALVES OR RESTRICTORS TO THE
OUTLET OF THE WATER HEATER.
• DO NOT FIT ANY OBSTRUCTION TO THE
PRESSURE RELIEF LOCATED ON THE HOT WATER
OUTLET CONNECTION.
Hot water supply
7.2 Freeze Prevention
Completely
insulate the
water inlet and
outlet fittings.
Do not cover the
water drain plug
with insulation.
The water in the
pipe can be drained.
Insulate the
water supply
valve completely.
Perform the following insulation measures for
prevention of freezing.
• Take appropriate heat insulation measures (e.g.
wrapping with heat insulation materials, using
heat tape, electric heaters, solenoids, or pipe
covers) according to the climate of the region
to prevent the plumbing external to the Water
Heater from freezing.
The freeze prevention heaters will not prevent
this plumbing from freezing.
• Make sure that there are no water leaks from the
cold and hot water supply lines, then insulate the
pipes completely.
• Be sure to also completely insulate the water
supply valve and the cold and hot water
connections on the Water Heater.
7.3 After Installing the water supply
piping
After purging the air from the system using the hot
water supply taps, remove the water inlet strainer
located on the cold water supply inlet connection.
Remove any debris from the filter and replace.
When replacing the filter, do not over-tighten the
Sealing.
For any sanitary fixture used for personal
hygiene, the delivered hot water temperature
shall not exceed 50˚C for Australia and 55˚C for
New Zealand.
For Australia, models which are not 50˚C
compliant should be fitted with a temperature
control device meeting the appropriate
plumbing code requirements.
WARNING
Commission Check for 50°C Temperature Delivery
A temperature check must be completed at the
nearest outlet to the Water Heater to ensure
delivered water is below 50°C.
To check the water temperature is below 50°C.
1. At the closest outlet adjust the hot water flow to
at least 5 litres/min.
2. After hot water has been running for 1 min
confirm the water temperature is below 50°C.
3. Turn the water off.
[(50°C Compliant Models Only) Minimum
Distances]
In order to comply with AS 3498 the minimum
distances as per the diagram below must be
observed.
Cold
: 15 mm (min) L: 2 m (min)
Closest hot
water outlet