[Gas pipe sizing tables]

•  These tables are for reference only. Consult gas pipe manufacturer for actual pipe capacities.

•  It is an example of Copper Pipe (AS 1432 TypeB) and Natural Gas.

•  Values in Table are in MJ of Gas per Hour. 

1. Maximum Natural Gas Delivery Capacity (For supply pressure around 1.25 kPa) - COPPER PIPE (AS 1432 TYPE B) [MJ/h]

Pipe

Size

0.12 kPa Pressure Drop

Length (including fittings) : metres

2

4

6

8

10

12

14

16

18

20

25

30

35

40

45

50

55

60

15

62

43

34

29

26

22

19

17

15

20

206

141

114

97

86

78

72

67

63

59

52

48

44

41

37

33

30

28

25

452

311

249

214

189

171

158

147

138

130

115

104

96

89

84

79

75

72

32

867

596

478

409

363

329

302

281

264

249

221

200

184

171

161

152

144

138

40

1459 1002

805

689

611

553

509

474

444

420

372

337

310

288

271

256

243

232

50

3356 2307 1852 1585 1405 1273 1171 1090 1022

966

856

776

713

664

623

588

559

533

65

6217 4273 3431 2937 2603 2358 2169 2018 1894 1789 1585 1436 1321 1229 1154 1090 1035

987

80

9884 6794 5455 4669 4138 3750 3450 3209 3011 2844 2521 2284 2101 1955 1834 1732 1645 1570

100

– 6286 5571 5048 4644 4320 4054 3829 3637 3469

125

– 11520 10210 9251 8511 7918 7429 7017 6665 6358

150

– 18531 16423 14881 13690 12736 11950 11288 10720 10227

2. Maximum Natural Gas Delivery Capacity (For supply pressure around 1.5-2.5 kPa) - COPPER PIPE (AS 1432 TYPE B)  [MJ/h]

Pipe 

Size

0.25 kPa Pressure Drop

Length (including fittings) : metres

2

4

6

8

10

12

14

16

18

20

25

30

35

40

45

50

55

60

15

93

64

51

44

39

35

32

30

258

20

306

210

169

145

128

116

107

99

93

88

78

71

65

61

57

54

51

49

25

672

462

371

318

281

255

235

218

205

193

171

155

143

133

125

118

112

107

32

1289

886

712

609

540

489

450

419

393

371

329

298

274

255

239

226

215

205

40

2170 1491 1197 1025

908

823

757

704

661

624

553

501

461

429

403

380

361

345

50

4993 3431 2755 2358 2090 1894 1742 1621 1521 1437 1273 1154 1061

987

926

875

831

793

65

9247 6355 5104 4368 3871 3508 3227 3002 2817 2661 2358 2137 1966 1829 1716 1621 1539 1469

80

14703 10105 8115 6945 6155 5577 5131 4773 4479 4231 3750 3397 3125 2908 2728 2577 2448 2335

100

– 9350 8287 7509 6908 6426 6030 5696 5409 5161

125

– 17136 15187 13761 12660 11777 11050 10438 9914 9458

150

– 27564 24429 22135 20363 18944 17775 16790 15946 15213

3. Maximum Natural Gas Delivery Capacity (For supply pressure around 2.75-5 kPa) - COPPER PIPE (AS 1432 TYPE B)  [MJ/h]

Pipe 

Size

0.75 kPa Pressure Drop

Length (including fittings) : metres

2

4

6

8

10

12

14

16

18

20

25

30

35

40

45

50

55

60

15

168

115

93

79

70

64

59

54

51

48

43

39

36

33

31

29

28

27

20

554

381

306

262

232

210

193

180

169

160

141

128

118

110

103

97

92

88

25

1218

837

672

575

510

462

425

396

371

351

311

281

259

241

226

214

203

193

32

2336 1606 1289 1104

978

886

815

758

712

672

596

540

497

462

433

409

389

371

40

3931 2702 2170 1857 1646 1491 1372 1276 1197 1131 1002

908

836

777

729

689

654

624

50

9046 6217 4993 4273 3787 3431 3157 2937 2755 2603 2307 2090 1923 1789 1678 1585 1506 1437

65

16754 11515 9247 7914 7014 6355 5847 5439 5104 4821 4273 3871 3562 3313 3109 2937 2789 2661

80

26639 18309 14703 12584 11153 10105 9297 8649 8110 7665 6794 6155 5663 5268 4943 4669 4435 4231

100

– 16941 15015 13604 12516 11644 10925 10320 9801 9350

125

– 31048 27517 24932 22938 21339 20022 18912 17962 17136

150

– 49941 44262 40104 36896 34324 32205 30421 28892 27564

Содержание TH32END5L

Страница 1: ...INSTALLER S MANUAL Gas Continuous Flow Water Heaters Installation Details Warranty Models TH32END5N TH32END5L TH32END6N TH32END6L SBB816T 1 Rev 12 20 ...

Страница 2: ...o hand the warranty to the customer along with the Owner s Guide The Water Heater must be commissioned including checking gas supply pressures at maximum demand The operation of the Water Heater should be explained including normal operation and regular maintenance CAUTION FOR CONTINUED SAFETY OF THIS APPLIANCE IT MUST BE INSTALLED OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER S INST...

Страница 3: ...4 Installation Clearances 10 5 Installation of the Water Heater 11 6 Connecting the Gas Supply 12 7 Connecting the Water Supply 17 8 Connecting Electricity 19 9 Remote Controller 21 10 Trial Operation 24 11 Plumbing Applications 26 12 Installation of the Quick Connect Multi System 27 13 Maintenance 28 ...

Страница 4: ...ARNING THIS APPLIANCE MUST ONLY BE INSTALLED IN ACCORDANCE WITH THE ACCEPTABLE PLUMBING CONFIGURATIONS SPECIFIED IN THESE INSTRUCTIONS FAILURE TO DO SO MAY RESULT IN CONDITIONS WHERE DELIVERY TEMPERATURE CONTROL IS INADEQUATE WARNING For NG Gas xx xxxxxxxx xx xx xx xx Do Not Use Appliance for Purposes Other Than Those Specified Do not use for other than increasing the temperature of the water supp...

Страница 5: ...Owner s Guide Installation Manual this document 1 each The following accessories are included with the Water Heater Check for any missing items before starting installation 2 1 Included Accessories 2 About the Water Heater ...

Страница 6: ...erformances 2 2 Specifications Model Name TH32END5 6 N TH32END5 6 L Type Installation Outdoor Wall mounted Air Supply Exhaust Power Flue Operating Pressure 200 1 000 kPa Minimum Flow Rate 2 0 L min Dimensions Height Width Depth 615 mm 464 mm 240 mm Weight 30 kg Water Holding Capacity 1 2 L Connection Sizes Water Inlet R 3 4 20 mm Hot Water Outlet R 3 4 20 mm Gas Inlet R 3 4 20 mm Power Supply Supp...

Страница 7: ...ER DRAIN VALVE PRESSURE RELIEF VALVE WATER DRAIN VALVE WIRING THROUGHWAY HOT WATER OUTLET WATER DRAIN VALVE WATER FILTER WIRING THROUGHWAY VIEW FROM TOP Unit mm 60 60 40 665 615 31 23 45 169 70 87 140 14 3 140 140 100 100 70 70 36 36 10 4 13 OBLONG HOLE EXHAUST TERMINAL 6 6 10 OBLONG HOLE HEIGHT OF EACH FITTINGS FROM BOTTOM OF CASE HOT WATER OUTLET COLD WATER INLET GAS INLET 44 55 51 ...

Страница 8: ...er Thermistor Burner Flame Rod Bypass Flow Control Valve Water Outlet Thermistor Heat Exchanger Thermistor Heat Exchanger High Limit Switch Thermal Fuse Ignition Plug Burner Burner Manifold Gas Valve Circuit Board Igniter Fan Motor Status Display Primary Gas Solenoid Valve Gas Proportioning Valve Anti frost Heater Anti frost Heater Anti frost Heater Anti frost Heater Pressure Relief Valve Cold Wat...

Страница 9: ... will cause carbon monoxide poisoning and a potential fire hazard DANGER Locate the appliance in an area where water leakage from the unit or connections will not result in damage to the area adjacent to the appliance or to the lower floors of the structure When such locations cannot be avoided it is recommended that a suitable drain pan adequately drained be installed under the appliance The pan ...

Страница 10: ...to be a source of ignition 4 For appliances not addressed above acceptance should be obtained from the Technical Regulator 5 Minimum clearances d and e also apply to any combustion air intake openings of appliances Ref Item Minimum clearances mm Fan assisted a Below eaves balconies and other projections Appliances up to 50 MJ h input 200 Appliances over 50 MJ h input 300 b From the ground above a ...

Страница 11: ...at it will not fall or move due to vibrations or earthquakes 1 Drill a single screw hole making sure to hit a stud 2 Insert and tighten the screw and hang the Water Heater by the upper wall mounting bracket 3 Determine the positions for the remaining four screws two for the top bracket and two for the bottom and remove the Water Heater Loca on of Screw Hole Moun ng Bracket upper Loca on of Screw H...

Страница 12: ... removal The thread diameter is 20 mm 2 Fit an suitably approved isolating gas cock in the supply pipe adjacent to the Water Heater gas connection 3 Ensure that the supply pipe and the gas pressure regulator ULPG or Natural Gas has sufficient flow capacity for this and other appliances connected to the fitting pipe 4 For ULPG appliances ensure that gas cylinders are of sufficient size The Water He...

Страница 13: ...nformation e g Point of delivery Outlet 1 clothes dryer 80 MJ h Outlet 2 range oven unit 50 MJ h Outlet 4 furnace 100 MJ h Outlet 3 water heater 150 MJ h 2 Determine the gas type used and supply gas Pressure and enter it Determine the piping material and enter it to the below Select the appropriate pipe sizing table from page 15 16 and enter it to the below Gas type Natural Pressure drop 0 12 kPa ...

Страница 14: ...section of piping Enter this size in the table below Appliance Demand Outlet length Size Outlet 1 80 MJ h 7 m 20 mm Outlet 2 50 MJ h 5 m 20 mm Outlet 3 150 MJ h 2 m 20 mm Outlet 4 100 MJ h 2 m 20 mm e g Appliance Demand Outlet length Size Outlet 1 Outlet 2 Outlet 3 Outlet 4 Section Demand Length Size a b Outlet 1 2 3 4 380 MJ h 12 m 40 mm b c Outlet 1 2 130 MJ h 4 m 20 mm c d Outlet 1 80 MJ h 7 m ...

Страница 15: ...62 371 318 281 255 235 218 205 193 171 155 143 133 125 118 112 107 32 1289 886 712 609 540 489 450 419 393 371 329 298 274 255 239 226 215 205 40 2170 1491 1197 1025 908 823 757 704 661 624 553 501 461 429 403 380 361 345 50 4993 3431 2755 2358 2090 1894 1742 1621 1521 1437 1273 1154 1061 987 926 875 831 793 65 9247 6355 5104 4368 3871 3508 3227 3002 2817 2661 2358 2137 1966 1829 1716 1621 1539 14...

Страница 16: ...329 311 295 2813 32 3399 2336 1876 1606 1423 1289 1186 1104 1035 978 867 785 723 672 631 596 566 540 40 5720 3931 3157 2702 2395 2170 1996 1857 1742 1646 1459 1322 1216 1131 1061 1002 952 908 50 13161 9046 7264 6217 5510 4993 4593 4273 4009 3787 3356 3041 2798 2603 2442 2307 2191 2090 65 24377 16754 13454 11515 10206 9247 8507 7914 7426 7014 6217 5633 5182 4821 4523 4273 4058 3871 80 38760 26639 2...

Страница 17: ...ch as possible to keep the piping simple Avoid piping in which an air holdup can occur Avoid connection by fluid seal It will cause the filter to stick that is torn Pipe and fittings must meet the installation requirements of AS NZS 3500 4 and local authority regulations An isolating valve must be installed on the water inlet in close proximity to the Water Heater A GATE VALVE OR BALL VALVE must b...

Страница 18: ...sure to also completely insulate the water supply valve and the cold and hot water connections on the Water Heater 7 3 After Installing the water supply piping After purging the air from the system using the hot water supply taps remove the water inlet strainer located on the cold water supply inlet connection Remove any debris from the filter and replace When replacing the filter do not over tigh...

Страница 19: ...turer Tie the redundant power cord outside the Water Heater Putting the redundant length of cord inside the Water Heater may cause electrical interference and faulty operation NOTE Do not let the power cord contact the gas piping Do not disconnect the electrical power when not in use When the power is off the freeze prevention in the Water Heater will not operate resulting in possible freezing dam...

Страница 20: ...Heater 2 Remove the front cover 4 screws 3 Pass the Quick Connect Cord through the wiring throughway and into the Water Heater 4 Plug the connector on the Quick Connect Cord to the connector inside the Water Heater 5 Connect the ground wire gray color wire to the screw at the base of the Water Heater 6 Secure the Quick Connect Cord with a clamp 7 Reattach the front cover 4 screws NOTE If the groun...

Страница 21: ...it only Works The Remote Controller used is different for general application one unit installation and piping applications Quick Connect Multi System Recirculation system Use remote controller cord for any extensions Install according to the National Electrical Code and all applicable local codes 1 Disconnect the electrical power to the Water Heater 2 Leave enough slack so that the remote control...

Страница 22: ...ting the temperature press MODE button again for 2 seconds If is displayed for a few seconds turn the power off at the power point and wait 10 seconds then turn the back on and repeat steps 3 1 to 4 The changing procedure of the maximum temperature setting 1 Turn the Water Heater off by pressing the Operation button on the Remote Controller NOTE Do not use the Water Heater while temperature settin...

Страница 23: ...8 50 55 60 75 37 48 50 C Quick Connect Multi System 2 units Recirculation system 55 C model only 1 unit only MODE button Maximum Temperature Setting Without Controller Main Controller Bath Room Controller ECM1T RC 9018C ECB1T ECB2T 50 C model TH32END5 N L Factory Setting 50 37 48 50 F03 37 37 48 37 48 55 C model TH32END6 N L Factory Setting 55 37 48 50 55 F03 37 37 48 37 48 50 37 48 50 60 37 48 50...

Страница 24: ... the Water Heater off and then back on 3 Reopen a hot water fixture 4 If necessary repeat until the air is completely purged from the gas pipe 5 Check that the hot water temperature changes by pressing the buttons Proceed to Step 6 5 To change ignition priority on the heaters press and hold the Maximum or Minimum burner set button on the circuit board repeat step 4 Press and hold the Maximum or Mi...

Страница 25: ...rol manual valve clockwise to the off position This Water Heater does not have a pilot It is equipped with an ignition device that automatically lights the burner Do not try to light the burner by hand 1 Read the safety information in the installation manual or on the right side of the Water Heater 2 Turn off all electrical power to the Water Heater 3 Do not attempt to light the burner by hand 4 T...

Страница 26: ...elay for Pump Optional 30 40 L Storage Tank To alleviate temperature fluctuation Globe Valve Gas Supply Aquastat Set the Aquastat to 5 C below the set output temperature An aquastat is the minimum pump control requirement in order to maintain the full recirculation warranty Pump Control Signal Pump Control Signal is the preferred method to control the recirculation pump A relay connection must be ...

Страница 27: ...ote Controller Cord Remote Controller Terminal Block Cord Connector Cord Connector Leave enough clearance around the plumbing to apply insulation It will be necessary to add bends to the piping to ensure that this clearance is available The backflow preventer should be placed upstream of the cold water branch Shutoff Valve Shutoff Valve Make this distance as short as possible The hot water tempera...

Страница 28: ...me periodically for a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned by a qualified service technician Water filter Check and clean the filter inside of cold inlet connection 13 1 Periodic Check Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace a...

Страница 29: ...le and generally Australian and New Zealand suburban water supplies fall within these limits parameters In areas of Australia and New Zealand where water may be supplied either fully or partly from bores artesian wells or similar one or more of the important limits may well be exceeded and the heater could therefore be at risk of failure Where uncertainty exists concerning water quality intending ...

Страница 30: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 30 ...

Страница 31: ...31 ...

Страница 32: ......

Отзывы: