background image

 

66 

 

Temperature Sensor Resistance Value Table for T1, T2, T3, T4 

°C 

°F 

 

°C 

°F 

 

°C 

°F 

 

°C 

°F 

 

-20 

-4 

115.266 

20 

68 

12.6431 

60 

140 

2.35774 

100 

212 

0.62973 

-19 

-2 

108.146 

21 

70 

12.0561 

61 

142 

2.27249 

101 

214 

0.61148 

-18 

101.517 

22 

72 

11.5 

62 

144 

2.19073 

102 

216 

0.59386 

-17 

96.3423 

23 

73 

10.9731 

63 

145 

2.11241 

103 

217 

0.57683 

-16 

89.5865 

24 

75 

10.4736 

64 

147 

2.03732 

104 

219 

0.56038 

-15 

84.219 

25 

77 

10 

65 

149 

1.96532 

105 

221 

0.54448 

-14 

79.311 

26 

79 

9.55074 

66 

151 

1.89627 

106 

223 

0.52912 

-13 

74.536 

27 

81 

9.12445 

67 

153 

1.83003 

107 

225 

0.51426 

-12 

10 

70.1698 

28 

82 

8.71983 

68 

154 

1.76647 

108 

226 

0.49989 

-11 

12 

66.0898 

29 

84 

8.33566 

69 

156 

1.70547 

109 

228 

0.486 

-10 

14 

62.2756 

30 

86 

7.97078 

70 

158 

1.64691 

110 

230 

0.47256 

-9 

16 

58.7079 

31 

88 

7.62411 

71 

160 

1.59068 

111 

232 

0.45957 

-8 

18 

56.3694 

32 

90 

7.29464 

72 

162 

1.53668 

112 

234 

0.44699 

-7 

19 

52.2438 

33 

91 

6.98142 

73 

163 

1.48481 

113 

235 

0.43482 

-6 

21 

49.3161 

34 

93 

6.68355 

74 

165 

1.43498 

114 

237 

0.42304 

-5 

23 

46.5725 

35 

95 

6.40021 

75 

167 

1.38703 

115 

239 

0.41164 

-4 

25 

44 

36 

97 

6.13059 

76 

169 

1.34105 

116 

241 

0.4006 

-3 

27 

41.5878 

37 

99 

5.87359 

77 

171 

1.29078 

117 

243 

0.38991 

-2 

28 

39.8239 

38 

100 

5.62961 

78 

172 

1.25423 

118 

244 

0.37956 

-1 

30 

37.1988 

39 

102 

5.39689 

79 

174 

1.2133 

119 

246 

0.36954 

32 

35.2024 

40 

104 

5.17519 

80 

176 

1.17393 

120 

248 

0.35982 

34 

33.3269 

41 

106 

4.96392 

81 

178 

1.13604 

121 

250 

0.35042 

36 

31.5635 

42 

108 

4.76253 

82 

180 

1.09958 

122 

252 

0.3413 

37 

29.9058 

43 

109 

4.5705 

83 

181 

1.06448 

123 

253 

0.33246 

39 

28.3459 

44 

111 

4.38736 

84 

183 

1.03069 

124 

255 

0.3239 

41 

26.8778 

45 

113 

4.21263 

85 

185 

0.99815 

125 

257 

0.31559 

43 

25.4954 

46 

115 

4.04589 

86 

187 

0.96681 

126 

259 

0.30754 

45 

24.1932 

47 

117 

3.88673 

87 

189 

0.93662 

127 

261 

0.29974 

46 

22.5662 

48 

118 

3.73476 

88 

190 

0.90753 

128 

262 

0.29216 

48 

21.8094 

49 

120 

3.58962 

89 

192 

0.8795 

129 

264 

0.28482 

10 

50 

20.7184 

50 

122 

3.45097 

90 

194 

0.85248 

130 

266 

0.2777 

11 

52 

19.6891 

51 

124 

3.31847 

91 

196 

0.82643 

131 

268 

0.27078 

12 

54 

18.7177 

52 

126 

3.19183 

92 

198 

0.80132 

132 

270 

0.26408 

13 

55 

17.8005 

53 

127 

3.07075 

93 

199 

0.77709 

133 

271 

0.25757 

14 

57 

16.9341 

54 

129 

2.95896 

94 

201 

0.75373 

134 

273 

0.25125 

15 

59 

16.1156 

55 

131 

2.84421 

95 

203 

0.73119 

135 

275 

0.24512 

16 

61 

15.3418 

56 

133 

2.73823 

96 

205 

0.70944 

136 

277 

0.23916 

17 

63 

14.6181 

57 

135 

2.63682 

97 

207 

0.68844 

137 

279 

0.23338 

18 

64 

13.918 

58 

136 

2.53973 

98 

208 

0.66818 

138 

280 

0.22776 

19 

66 

13.2631 

59 

138 

2.44677 

99 

210 

0.64862 

139 

282 

0.22231 

 

 

Содержание 12H47YIMI

Страница 1: ...7 22 2021 SINGLE ZONE MINISPLIT SERVICE MANUAL For the following models 9H47YIMI 9H47YOMI 12H47YIMI 12H47YOMI 12H47ZIMI 12H47ZOMI 18H47ZIMI 18H47ZOMI 24H46ZIMI 24H46ZOMI 30H48ZIMI 30H48ZOMI 36H46ZIMI...

Страница 2: ...iring Diagram 17 5 1 Indoor Unit 17 5 2 Outdoor Unit 18 6 Installation Details 22 6 1 Wrench Torque Sheet 22 6 2 Cable Connection Sheet 22 6 3 Pipe Size Length and Elevation 22 6 4 First Time Installa...

Страница 3: ...Set up Steps 41 8 5 1 Set up Manual 41 9 Troubleshooting 43 9 1 Indoor Unit Error Codes 44 9 2 Diagnosis and Solution 45 9 2 1 E0 F4 EEPROM Parameter Error 45 9 2 2 E1 Indoor Outdoor Communication Err...

Страница 4: ...N 69 9 3 6 Pressure on Service Port 70 10 Unit Disassembly 72 10 1 Indoor Unit 72 10 1 1 Accessing the Terminal Block 72 10 1 2 Removing the Front Cover Housing 73 10 1 3 Removing the Indoor PCB 75 10...

Страница 5: ...ed circuit breaker Use this appliance on a dedicated circuit For electrical work contact the dealer seller a qualified electrician or an authorized service center Always ground the product Install the...

Страница 6: ...pecial purposes such as preserving foods works of art etc It is a consumer air conditioner not a precision refrigeration system Do not block the inlet or outlet of air flow Use a soft cloth to clean D...

Страница 7: ...C Rated Voltage Y 115V Z 230V D Type of unit I Indoor unit O Outdoor unit X Internal Code Indoor Outdoor Voltage V Capacity BTU Heat Pump 9H47YIMI 9H47YOMI 115 9 000 X 12H47YIMI 12H47YOMI 12 000 X 12...

Страница 8: ...ul gases and odors Follow Me With this feature a temperature sensor is built into the remote control The unit will use that temperature sensor for the ambient temperature so the air conditioner is fol...

Страница 9: ...l easily dissolves in refrigerant especially in low temperature conditions The crankcase heating belt can heat the bottom of the compressor to avoid pumping out too much oil with the refrigerant which...

Страница 10: ...10 1080 mm 226 mm 335 mm 30H48ZIMI 49 57 1259 mm 11 1 282 mm 14 25 362 mm 36H46ZIMI...

Страница 11: ...1 7 Right rear wall hole 2 5 Indoor Unit Outline 28 43 9K 31 57 12K 1 7 1 7 1 1 7 Left rear wall hole 2 5 8 6 22 87 1 3 2 37 99 18K 42 52 24K 2 1 1 8 5 3 2 1 1 8 5 5 85 5 95 6 86 Indoor Unit Outline R...

Страница 12: ...above is for reference only The appearance of actual units may be different Model W D H W1 A B 9H47YOMI 30 31 770 mm 11 81 300 mm 21 85 555 mm 32 40 823 mm 20 87 530 mm 11 42 290 mm 12H47YOMI 12H47ZO...

Страница 13: ...4 1 Refrigerant Cycle Diagram For models 9H47YOMI 12H47YOMI 12H47ZOMI 18H47ZOMI 24H46ZOMI LIQUID SIDE GAS SIDE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR 2 WAY VALVE 3 WAY VALVE 4 WAY...

Страница 14: ...VAPORATOR HEAT EXCHANGE CONDENSER Compressor 2 WAY VALVE 3 WAY VALVE 4 WAY VALVE COOLING HEATING T2 Evaporator temp sensor T1 Room temp sensor T3 Condenser temp sensor T5 Discharge temp sensor T4 Ambi...

Страница 15: ...city BTU Outdoor Temoerature F 12K 80F 17052 18900 18000 15243 0 5000 10000 15000 20000 75F 85F 95F 105F Capacity BTU Outdoor Temoerature F 18K 80F 22540 24485 24000 20152 0 5000 10000 15000 20000 250...

Страница 16: ...2547 10116 7685 4425 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 57F 47F 37F 17F 5F 5F 13F Capacity BTU Outdoor Temoerature F 18K 55F 70F 28547 26521 22022 17523 13688 9852 5623 27412 25...

Страница 17: ...17 5 Wiring Diagram 5 1 Indoor Unit For models 9H47YIMI 12H47YIMI 12H47ZIMI 18H47ZIMI 24H46ZIMI For models 30H48ZIMI 36H46ZIMI...

Страница 18: ...18 5 2 Outdoor Unit Model Voltage V Capacity BTU Type 9H47YOMI 115 9 000 HEAT PUMP 12H47YOMI 115 12 000 HEAT PUMP...

Страница 19: ...19 Model Voltage V Capacity BTU Type 12H47ZOMI 230 12 000 HEAT PUMP...

Страница 20: ...20 Model Voltage V Capacity BTU Type 18H47ZOMI 230 18 000 HEAT PUMP 24H46ZOMI 230 24 000 HEAT PUMP...

Страница 21: ...21 Model Voltage V Capacity BTU Type 30H48ZIMI 230 30 000 HEAT PUMP 36H46ZIMI 230 36 000 HEAT PUMP...

Страница 22: ...unit Please refer to the nameplate before selecting the cable fuse and disconnect box The supply power cable should be selected according to the specifications sheet shown below Appliance Amps AWG Wi...

Страница 23: ...m 6 4 1 Gas Leak Check Soap Water Method Apply soap water or a neutral liquid detergent to the indoor unit line set connections and service ports with a soft brush If bubbles start forming there is a...

Страница 24: ...en retighten the flare nut Make sure the pressure display in the pressure indicator is 10 psi higher than the atmosphere pressure Then remove the charge hose from the 3 way valve 8 Fully open the 2 wa...

Страница 25: ...lays the proper weight refer to the gauge and the pressure of the low side disconnect the charge hose from the 3 way valve s service port immediately and turn off the air conditioner before disconnect...

Страница 26: ...he charge hose Open the Handle Lo valve of the manifold valve slightly to purge air from the charge hose for 5 seconds and then close it quickly 4 Set the 2 way valve to the close position 5 Operate t...

Страница 27: ...ect the vacuum pump to 3 way valve s service port 3 Evacuation for approximately two hours Confirm that the compound meter indicates 500 microns mHg 4 Close the valve low side on the charge set turn o...

Страница 28: ...on the charge set and charge the system with liquid refrigerant If the system cannot be charged with the specified amount of refrigerant or can be charged with a little at a time approximately 5oz or...

Страница 29: ...y should be less than 80 If the air conditioner operates beyond this figure the surface of the air conditioner may attract condensation Please set the vertical air flow louver to its maximum angle ver...

Страница 30: ...ed or Timer OFF is activated This code illuminates when unit is defrosting This code illuminates when anti cold air function is turned on This code illuminates when unit is in self cleaning process Th...

Страница 31: ...because the refrigerant system was designed to operate at a specific safety pressure If the pressure gets too high the compressor may get overload and an explosion may even occur in extreme circumsta...

Страница 32: ...ctivated the compressor will run with low frequency When the current is more than setting value the current protection function will be activated and the compressor will stop 8 4 2 2 Outdoor Fan Logic...

Страница 33: ...or temperature protection The compressor will stop when the evaporator temperature below the setting value 8 4 3 Heating Mode 8 4 3 1 Compressor Operation Logic When T1 Ts T the compressor will stop w...

Страница 34: ...the compressor is on the indoor fan can be set to high med low auto And the anti cold wind function has the priority The indoor fan is controlled as below Setting fan speed Actual fan speed H H H G A...

Страница 35: ...for 15 minutes in defrosting mode 8 4 3 5 Evaporator temperature protection Off Compressor stops Decrease Decrease the running frequency to the lower level Hold Keep the current frequency Resume No li...

Страница 36: ...he same as normal auto mode with 75 F setting temperature When AC receives signals from the remote control such as switch on switch off timer on timer off mode setting fan speed setting sleeping mode...

Страница 37: ...hutting down its louver will restore to the angle originally set by the user but the precondition is that the angle must be within the allowable range if it exceeds it will memorize the maximum angle...

Страница 38: ...hen the Silence function is activated the compressor running frequency will keep in low and the indoor unit will bring faint breeze which will reduce the noise to the lowest level and create a quiet a...

Страница 39: ...ween 5 9 6 5 3 6 2 Between 6 6 7 8 7 2 3 Between 7 9 8 5 10 8 4 Note See Setup Manual on page 37 for changing Enquiry information Displaying code Meaning T1 T T1 Room temperature T2 T T2 Indoor coil t...

Страница 40: ...19 99 A0 A1 A9 100 101 109 b0 b1 b9 110 111 119 c0 c1 c9 120 121 129 d0 d1 d9 130 131 139 E0 E1 E9 140 141 149 F0 F1 F9 150 151 159 Indoor fan speed Outdoor fan speed 0 OFF 1 2 3 4 Low speed Medium sp...

Страница 41: ...OFF to select the setup range Press TIMER ON to confirm and exit 8 5 1 Set up Manual Note All temperature here is in Celsius Setup Manual Setup Code Setup Name Setup Range Display on remote indoor un...

Страница 42: ...reminder ON After 2 880 hours of use nF will flash on the indoor panel for 15 seconds each time when the unit restarts OFF OFF E2 lowest setting temperature 17 C 24 C 62 F 76 F 17 C 24 C 62 F 76 F 17...

Страница 43: ...Do not forget to discharge the electricity in the capacitors before troubleshooting Electrolytic Capacitors CAUTION HIGH VOLTAGE For other models please connect the discharge resistance approximately...

Страница 44: ...r discharge temperature sensor T5 open circuit or short circuit F4 Outdoor unit EEPROM parameter error F5 Outdoor fan speed has been out of control P0 IPM malfunction or IGBT over strong current prote...

Страница 45: ...eplace the main PCB directly Otherwise check whether the EEPROM chip plugged in main PCB well Yes No Yes Correct the connection Replace the main PCB Shut off the power supply and turn it on 5 seconds...

Страница 46: ...later No Replace the outdoor main PCB Power on Is the error extinguished Replace the outdoor main PCB Power on Is the error extinguished Check the outdoor wiring connection Check the outdoor wiring co...

Страница 47: ...the voltage will move alternately between 25V to 25V If the outdoor unit is faulty the voltage will move alternately with positive value If the indoor unit is faulty the voltage will be a specific val...

Страница 48: ...edback for four 4 minutes or the zero crossing signal time interval is abnormal Possible Causes Wiring mistake PCB faulty Check if the connections and power supply is normal Correct the connections Tu...

Страница 49: ...PCB faulty Power off then restart the unit 2 minutes later Shut off the power supply Rotate the fan by hand The unit operates normally Find out the cause and have it solved Check the wiring of fan mot...

Страница 50: ...2 3 Black GND 0V 4 White Vcc 14 17 5V 5 Yellow Vsp 0 5 6V 6 Blue FG 14 17 5V 2 Outdoor DC Fan Motor control chip is in outdoor PCB Power on and check if the fan can run normally if the fan can run no...

Страница 51: ...ible Causes Wiring mistake Sensor faulty Check the connection between temperature sensor and PCB Correct the connection No Yes Replace indoor or outdoor main PCB Measure the resistance value of the se...

Страница 52: ...artup During the first five 5 minutes of starting up if T2 TC 3 8 F 2 C does not hold for four 4 continuous seconds three 3 times Possible Causes T2 sensor faulty Indoor PCB faulty Refrigerant system...

Страница 53: ...ent Protection Condition An abnormal current rise is detected by checking the specified current detection circuit Possible Causes Wiring mistake Power supply problems System blockage Compressor malfun...

Страница 54: ...in PCB and compressor Correct the connection or replace the wires and connectors Yes No Check the IPM No Yes Replace the IPM board or replace the main PCB Check the outdoor fan and the outdoor unit ve...

Страница 55: ...55 Note The pictures below are only for reference they may be not same as the ones on your unit P U P V...

Страница 56: ...56 P W N U...

Страница 57: ...57 N V N W...

Страница 58: ...he resistance between every two ports of U V W of IPM and P N If any result of them is 0 or close to 0 the IPM is defective and has to be replaced Otherwise please follow the procedure below Refer to...

Страница 59: ...B faulty Check the power supply Check the connections and wires Stop the unit No Yes No Correct the connections or replace the wires Yes Replace the reactor Yes No Replace the IPM board Check the volt...

Страница 60: ...r up the air inlet and outlet or the heat exchanger of indoor and outdoor units Yes No Yes Yes Power off then restart the unit 10 minutes later Check if the temperature of compressor No Check refriger...

Страница 61: ...tection voltage detection compressor rotation speed signal detection etc Possible Causes Wiring mistake IPM malfunction Outdoor fan assembly faulty Compressor malfunction Outdoor PCB faulty For 9K to...

Страница 62: ...ery two ports of U V W of IPM and P N first If any result of them is 0 or close to 0 the IPM is defective and has to be replaced Otherwise please follow the procedure below Refer to Section 9 3 5 Plea...

Страница 63: ...value the pressure protector will switch off After the pressure resume to normal the protection code will extinguish Possible Causes Wiring mistake Pressure protector faulty Outdoor fan assembly fault...

Страница 64: ...e value of each winding by using the multimeter Position Resistance 68 F 20 C 9H47YOMI ASN98D22UFZ 12H47YOMI ASN98D22UFZ 12H47ZOMI ASN98D22UFZ 18H47ZOMI ASM135D23UFZ 24H46ZOMI ATF235D22UMT 30H48ZOMI A...

Страница 65: ...the resistance using a multimeter The variables for the different temperature sensors are shown below T1 Room temperature sensor T2 Indoor coil temperature sensor T3 Outdoor coil temperature sensor T4...

Страница 66: ...38991 2 28 39 8239 38 100 5 62961 78 172 1 25423 118 244 0 37956 1 30 37 1988 39 102 5 39689 79 174 1 2133 119 246 0 36954 0 32 35 2024 40 104 5 17519 80 176 1 17393 120 248 0 35982 1 34 33 3269 41 10...

Страница 67: ...34 93 37 3 72 162 8 94 110 230 2 781 3 27 211 4 35 95 35 78 73 163 8 643 111 232 2 704 2 28 200 7 36 97 34 32 74 165 8 358 112 234 2 63 1 30 190 5 37 99 32 94 75 167 8 084 113 235 2 559 0 32 180 9 38...

Страница 68: ...table below for proper resistance values Position Resistance Red Black Several M P N U V W U N V W Red 9 3 4 Outdoor AC Fan Motor Check To check if the outdoor fan motor is working properly measure t...

Страница 69: ...mal Voltage on P and N 208 240VAC 1 phase 3 phase 380 420VAC 3 phase Standby Around 310 VDC Around 530 VDC Operating With passive PFC module With partial active PFC module With fully active PFC module...

Страница 70: ...ODT IDT 75 23 89 85 29 44 95 35 105 40 56 115 46 11 PSI 70 59 119 113 117 125 147 PSI 75 63 124 120 126 132 155 PSI 80 67 135 129 132 140 162 F C ODT IDT 75 23 89 85 29 44 95 35 105 40 56 115 46 11 MP...

Страница 71: ...37 33 2 78 0 56 27 23 2 78 5 17 13 8 33 10 56 PSI 55 439 413 367 330 302 PSI 65 471 435 386 368 339 PSI 75 489 457 403 381 362 F C ODT IDT 57 53 13 89 11 67 47 43 8 33 6 11 37 33 2 78 0 56 27 23 2 78...

Страница 72: ...units The model used for the demonstration down below is the 24H45YZIMI 24H45ZOMI 10 1 Indoor Unit 10 1 1 Accessing the Terminal Block Follow the following steps to gain access to the terminal block...

Страница 73: ...ottom of the unit under the front cover Number of screws will depend on model 2 Remove the screws located under the front flip up cover Additional screws maybe hidden under the horizontal louver cover...

Страница 74: ...ving the front cover housing be aware there is a wire connecting the cover housing and the indoor PCB Be sure to disconnect this connector 5 When the front cover housing is removed the unit can be pro...

Страница 75: ...the Indoor PCB First follow the steps to remove the front cover housing from the previous section then follow the steps below to remove the indoor PCB 1 First remove the screw holding the cover on th...

Страница 76: ...ok the clip 3 Lift the cover up from the bottom and pull out to remove cover The picture on the right shows what the electronics box looks like with the cover removed NOTE The connections shown below...

Страница 77: ...the top of the terminal block 7 Disconnect the transformer primary connector 8 Disconnect the CN3 evaporator coil sensor 9 Disconnect the CN1 ambient temperature sensor 10 Disconnect the indoor fan m...

Страница 78: ...cted to gain access to other connectors that need to be disconnected 1 Remove the screw for the ground wire in the location shown above 2 Remove the screw on the bottom of the electronics box See pict...

Страница 79: ...Unit 10 2 1 Removing the Outdoor PCB 1 Remove the nine 9 screws on the top lid of the condenser unit 2 Lift and remove the lid from the top of the unit 3 Remove the two screws on the side panel of th...

Страница 80: ...80 4 There are hooks on the side edges of the side panel First push down on the panel to unhook it and then pull it forward to remove Picture of outdoor unit with side panel removed...

Страница 81: ...Remove the wires from the clips holding them in place 6 There are four tabs that hold the plastic of the PCB in place Use a flathead screwdriver or some kind of wedging tool if necessary to unhook the...

Страница 82: ...82 7 Then lift the PCB assembly off the unit NOTE All wires are still connected...