POOL+ MANAGER App A2 - User Manual v1.0
3
POOL SENSOR
The pool sensor must be fitted into the heating
circuit, upstream of the heater and preferably in a
position out of direct sunlight. It is recommended
that a 14.5mm hole be drilled in the side of the PVC
pipe (not the top of the pipe where water will
collect), this can be carried out using a Theralux
PD01 grinding drill or a small pilot hole can be
drilled with a 14.0mm drill-bit used spinning in a
counter clockwise direction to minimize the
chance of shattering pipe. Insert the grommet into
the pipe and gently push in the sensor barb. Ideally
~30cm of the cable from the sensor should be tied
to the shaded side of the pipe to prevent extreme
ambient conditions leeching into the sensor via the
copper in the cable. The blue sensor plug is to be
fitted to either Sensor 1 or 2 port located beneath
the controller (see diagram on p 4).
ROOF SENSOR
If a roof sensor is installed, it must be fitted into a
small piece of collector material away from the
main collector but on the same aspect, preferably
no more than 50cm from the roof gutter (for ease
of sensor replacement). If required, the roof sensor
can be on a different roof as the solar collector as
long as the alignment to the sun is similar to the
solar collector. For encapsulated collector panels
use the manufacturer’s instructions for roof sensor
placement. The red sensor plug is to be fitted to
either Sensor 1 or 2 port located beneath the
controller (see diagram on p 4).
SENSOR NOTES:
All excess cable must be removed;
coils of cable are not permitted under any
circumstances and
must not
be tied to 240V
wiring. If the cable is to be extended with non-
genuine cable a size of 14/020 should be used.
Any
cable joins should be soldered
. Heat shrink is to be
used over soldered joints to eliminate moisture
ingress.
EXPANSION UNITS
The Pool+ Manager A2 has the capacity to have an additional 2 expansion units connected to it. Each
Expansion Unit has an additional 3, 240VAC Output sockets that are controlled via the Pool+ Manager A2
controller. Up to an additional 6 power sockets can be utilised and controlled by the Pool+ Manager A2 master
controller.
The Expansion Units are rated at either 10Amps or 15Amps. All 3 sockets of the Expansion Unit are rated the
same. 3 sockets at 10Amps or 3 sockets at 15Amps.
EXPANSION UNIT MOUNTING
Find a suitable location to mount the control box.
Ideally, as with all pool equipment, it should be
installed out of direct weather and no closer than
3 metres from the water’s edge, at a minimum
600mm above ground. The power cable is 1.8m
long and should be plugged directly into a general
power outlet, not into an extension lead.
Mount as per main controller.
POWER OUTPUT CONNECTIONS
The 240VAC Output Sockets are for equipment to
be controlled via the Pool+ Manager A2. Each
socket can be assigned via the menu and/or app.
The maximum combined load for all three sockets
of the module is either, 9.98 Amps / 2340 Watts,
or, 14.98 Amps / 3540 Watts. Please refer to the
unit’s rating label.
The 15Amp rated expansion unit must be plugged
into a 15Amp rated GPO.