3-23
Themis Computer
BIOS Setup Utility
Advanced Setup Configurations
es’, the installed CPU can now send its ‘Temperature Tolerance’ to the moth-
erboard resulting in better CPU thermal management.
Supermicro has leveraged this feature by assigning a temperature status to
certain thermal conditions in the processor (Low, Medium, and High). This
makes it easier for the user to understand the CPU’s temperature status,
rather than by just simply seeing a temperature reading (i.e., 25
o
C). For more
information on thermal management, please refer to Intel’s Website at
www.Intel.com.
2.
To avoid possible overheating, be sure to provide adequate airflow to the sys-
tem.
3.3.8.3 IOH Temperature
This feature displays the absolute Input/Output Hub (IOH) temperature (i.e., 51
o
C).
3.3.8.4 System Temperature
This feature displays the absolute system temperature (i.e., 34
o
C).
3.3.8.5 Fan1—Fan 6 Reading
This feature displays the fan speed readings from fan interfaces Fan1 through Fan6.
3.3.8.6 Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase for effective sys-
tem cooling. Select Full Speed to allow the onboard fans to run at full speed (of
100% Pulse Width Modulation Duty Cycle) for maximum cooling. The Full Speed
setting is recommended for special system configuration or debugging. Select Per-
formance for the onboard fans to run at 70% of the Initial PWM Cycle for better sys-
tem cooling. The Performance setting is recommended for high-power-consuming
and high-density systems. Select Balanced for the onboard fans to run at 50% of the
Initial PWM Cycle in order to balance the needs between system cooling and power
saving. The Balanced setting is recommended for regular systems with normal hard-
ware configurations. Select Energy Saving for the onboard fans to run at 30% of the
Initial PWM Cycle for best power efficiency and maximum quietness. The Options
are: Full Speed/FS (@100% of PWM Cycle) (default), Performance/PF (@70% of
PWM Cycle), Balanced/BL (@50% of PWM Cycle), and
Energy Saving/ES
Содержание RES - 32XR3
Страница 16: ...xiv Themis Computer RES 21XR3 for X8SAX Installation Manual...
Страница 20: ...xviii Themis Computer RES 21XR3 for X8SAX Installation Manual...
Страница 100: ...3 34 Themis Computer RES 21XR3 for X8SAX Installation Manual...
Страница 106: ...A 6 Themis Computer RES 21XR3 for X8SAX Installation Manual...
Страница 110: ...Themis Computer RES 21XR3 for X8SAX Installation Manual B 4...
Страница 134: ...E 4 Themis Computer RES 21XR3 for X8SAX Installation Manual...