INTRODUCTION AND SAFETY 
INFORMATION 

Thelin Co., Inc. would like to thank you for choosing 
our  Parlour  3000  Direct  Vent  Gas  appliance. 
Whether you are hooking up to a natural gas or liquid 
propane  gas,  please  read  the  following  safety 
information thoroughly  before installing or lighting 
your new gas heater. Improper installation will void 
your  warranty,  but,  more  importantly,  incorrect 
installation  and/or  hook-up  could  result  in  serious 
injury and even loss of life. Follow these instructions 
closely  and  do  not  deviate  from  them  without  the 
permission  of  licensed  and  trained  personnel 
knowledgeable  of  the  installation  and  operation  of 
gas appliances. 

If You Smell Gas: 

 

Extinguish any open flame. 

 

Do not light any appliance. 

 

Do not plug in or unplug any electrical plug or 
switch. 

 

Open windows and vacate building. 

 

Call gas supplier from a phone outside of your 
house  or  if  unable  to  reach  supplier,  call  fire 
department  (also  from  phone  outside  of  your 
house). 

Safety Check Before Installation 

This  appliance  must  be  installed  by  a  licensed  and 
qualified  installer  to  prevent  the  possibility  of 
explosion.  This  instruction  manual  must  be  strictly 
adhered  to.  Do  not  use  makeshift  methods  or 
compromise  the  installation  in  any  way.  Improper 
installation will void the warranty and safety listing. 

This appliance is approved for either natural gas or 
LP  (liquid  propane)  gas.  Burning  the  incorrect  fuel 
will  void  the  warranty  and  safety  listing  and  could 
cause  extreme  hazard.  Make  sure  you  have  the 
proper  gas  valve  for  the  fuel  being  used.  The  gas 
valve is clearly marked natural gas or LP gas. This 

marking can be found on the back of the stove above 
the gas line (see Figure 1)

Permit 

Contact  your  local  building  officials  and  obtain  a 
permit  before  beginning  installation.  Notify  your 
insurance company and provide them with the proper 
inspection  documents  indicating  that  the  appliance 
has  been  installed  to  code  and  inspected  and  also 
passed inspection. 

Flammables 

Do  not  store  or  use  gasoline  or  other  flammable 
liquids in the vicinity of the heater. 

Airflow 

Always  keep  control  compartment  and  fan  air 
passageways  free  of  lint  and  dust  and  obstructions 
(see  Figure  11).  Do  not  place  clothing  or  other 
flammable items on or near the heater. The heater can 
be  controlled  by  a  thermostat  and  will  come  on 
automatically if the thermostat option is hooked up 
and utilized. 

Educate small children that external 

portions of the heater  are extremely  hot! Young 
children  should  be  supervised  if  they  are  in  the 
same room with the heater.

 

Safe Operation 

Operate  this  heater  in  accordance  with  the 
instructions in this manual. Light the pilot and burner 
using  built-in  piezo  lighter.  Do  not  use  matches  or 
any other lighting device external to your appliance. 
If the pilot or main burner do not light correctly, turn 
off the gas at the gas control valve (see Figure 8), and 
call  your  dealer  or  service  person.  If  the  flame 
becomes  sooty,  dark  orange  in  color,  or  extremely 
tall  and  lazy,  do  not  operate  the  heater.  Call  your 
dealer. Do not operate the heater if any portion of the 
heater has been submerged in water or any corrosion 
occurs. Do not operate if you suspect any improper 
operation. Call your dealer.  

Содержание PARLOUR 3000-MV

Страница 1: ...tructions CUSTOMER PLEASE KEEP INSTRUCTIONS FOR FUTURE REFERENCE INSTALLER PLEASE LEAVE THIS MANUAL WITH THE CUSTOMER PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION SAVE THESE INSTRUCTIONS Parlour...

Страница 2: ...led and maintained or a house fire may result For your safety follow the installation instructions Contact local building officials about restrictions and installation inspection Failure to comply wit...

Страница 3: ...E APPLIANCE BE KEPT CLEAN IT IS IMPERATIVE THAT CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE ARE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OU...

Страница 4: ...with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Listing and Codes The Parlor is listed and certified for i...

Страница 5: ...pection 24 Floor Protection 14 Gas Control Knob 21 Gas Data 14 Gas Leaks 2 7 Gas Line Installation 21 Gas Valve 33 Glass Replacement 26 Gold polishing 26 Hi Lo Flame Adjust 21 Horizontal Installation...

Страница 6: ...nts 18 Figure 6 Vent Termination 20 Figure 7 Location of Pilot Burners and Logs 22 Figure 8 Diagram of Control Components 23 Figure 9 Wiring Diagram 29 Figure 10 Directions for Enabling Door Opening a...

Страница 7: ...he vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT TRY TO LIGHT ANY APPLIANCE DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT TURN ON ANY LIGHTS OR LAMPS DO NOT USE ANY PHONE IN Y...

Страница 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...

Страница 9: ...sure you have the proper gas valve for the fuel being used The gas valve is clearly marked natural gas or LP gas This marking can be found on the back of the stove above the gas line see Figure 1 Perm...

Страница 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...

Страница 11: ...GAS HEATER 11 FIGURE 2 CLEARANCE TO COMBUSTIBLES Please use these diagrams to place your stove in the room Please note Cornerwall means from the back of the stove to the corner Unit to corner 10 Cente...

Страница 12: ...rants no warranty implied or stated for the installation and maintenance of your heater and assumes no responsibility of any consequential damages as a result of improper installation or failure to pe...

Страница 13: ...RMATION Factory installed orifices are as follows Natural Gas 39 up to 4 500 elevation LP Gas 53 up to 4 500 elevation Recommendation If installing at higher altitudes Thelin Co recommends at the disc...

Страница 14: ...om heater should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or...

Страница 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...

Страница 16: ...gulator assembly U S Installation Clearance in accordance with local installation codes and the requirements of the gas supplier I Clearance to service regulator vent outlet U S Installation Clearance...

Страница 17: ...r requirements For horizontal installations determine the minimum clearance from the rear of the appliance to the wall see the Listing Label It is also important to note the wall thickness Select the...

Страница 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...

Страница 19: ...les Any components with these symptoms must be replaced 2 Remove the termination cap and shine a flashlight down the vent pipe Remove any bird nests or other foreign material 3 Check for evidence of e...

Страница 20: ...nstallation involves a roof with a slope greater than 6 12 or if a wall or other vertical obstruction is within 8 of the vent termination the vent termination will have to be taller in accordance with...

Страница 21: ...essed it creates a spark at the pilot igniting it Burner On Off Switch This switch turns the burner on after the pilot is lit When the wall thermostat is hooked up this switch will remain in the On po...

Страница 22: ...nutes The pilot flame must cover the tip of the thermocouple and thermopile probes If the pilot flame does not sufficiently cover the probes it can be adjusted using the pilot adjustment screw found o...

Страница 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...

Страница 24: ...sound as the fan turns on These sounds are all normal WARNING Do not burn heater if glass is cracked or broken See Maintenance for replacing glass MAINTENANCE Make sure that there is adequate clearanc...

Страница 25: ...switch to ON position TO TURN OFF GAS TO APPLIANCE A This appliance has a pilot which is lit with a push button piezo lighter When lighting the pilot follow these instructions exactly BEFORE LIGHTING...

Страница 26: ...lass by slamming door or striking foreign object against glass Do not clean glass with abrasive cleanser or when hot Polishing the Gold and Chrome All gold and chrome plating used on the Parlour can b...

Страница 27: ...ned off The gas control valve is turned to pilot The gas control valve wasn t pushed in and or the igniter wasn t pushed repeatedly Main burner does not come on The pilot has gone out The burner on of...

Страница 28: ...only parts that the consumer may replace All other parts must be replaced by a qualified gas service person PART DESCRIPTION Door Gasket White 3 8 dia fiberglass rope 51 long Glass Gasket Tape Knit Hy...

Страница 29: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 29 FIGURE 9 WIRING DIAGRAM Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation...

Страница 30: ...ation of this product not manufactured by Thelin Co Inc THIS LIMITED WARRANTY IS THE ONLY WARRANTY SUPPLIED BY THELIN CO INC UNLESS AN EXTENDED WARRANTY HAS BEEN PURCHASED THE MANUFACTURER OF THE UNIT...

Страница 31: ...0 DIRECTIONS FOR ENABLING DOOR OPENING AND SECURING DOOR Cleaning Glass 1 Turn off stove and let cool down 2 Open door and clean glass with glass cleaner i e Windex or similar product and wipe with so...

Страница 32: ...1 DELAYED IGNITION SAFETY DOOR This unit is equipped with a safety door system that will prevent damage if the stove ignites with delayed combustion If this happens you must have a qualified service p...

Страница 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...

Страница 34: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 34 APPENDIX A VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...

Страница 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...

Страница 36: ...l rear log 2 against brick panel and center right to left 3 Place small log 3 with the notch on the bottom setting of the ledge indicated in the illustration 4 Rest the Y log 4 on top of the small log...

Страница 37: ...ATER APPENDIX C PYROTECH LOG PLACEMENT CONTINUED 5 Place the front log 5 against the Y log in the notch shown in the illustration with the bottom end up against the lip of the door opening Note The bo...

Страница 38: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER Thelin Hearth Products Inc 63 Laxalt Dr Carson City NV 89706 www thelinco com 775 241 2586...

Отзывы: