PARLOUR 3000-MV
DIRECT VENT GAS HEATER
3
SAFETY NOTICES
IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, A HOUSE FIRE, OR EXPLOSION MAY RESULT.
FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR
FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION REQUIREMENTS IN YOUR AREA.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW APPLIANCE.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR
DEATH. DO NOT OPERATE WITH DOOR OPEN!
Safe installation and operation always require
common sense. We are also required by
Canadian and ANSI safety standards to point out
the following:
INSTALLATION AND REPAIR SHOULD BE
DONE BY A QUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED
BEFORE USE AND AT LEAST ANNUALLY BY
A PROFESSIONAL SERVICE PERSON. MORE
FREQUENT CLEANING MAY BE REQUIRED
DUE
TO
EXCESSIVE
LINT
FROM
CARPETING,
BEDDING
MATERIAL,
ET
CETERA. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS,
BURNERS
AND
CIRCULATING AIR PASSAGEWAYS OF THE
APPLIANCE BE KEPT CLEAN.
IT
IS
IMPERATIVE
THAT
CONTROL
COMPARTMENTS,
BURNERS
AND
CIRCULATING AIR PASSAGEWAYS OF THE
APPLIANCE ARE KEPT CLEAN.
DUE
TO
HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES AND SHOULD
STAY AWAY TO AVOID
BURNS
OR
CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN THE
SAME ROOM AS THE APPLIANCE.
CLOTHING
OR
OTHER
FLAMMABLE
MATERIALS SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
“THE FLEXIBLE CORD PROVIDED MUST BE
CONNECTED TO A LINE VOLTAGE
ELECTRICAL SUPPLY”.
ANY
SAFETY
SCREEN
OR
GUARD
REMOVED
FOR
SERVICING
A
ROOM
HEATER MUST BE REPLACED PRIOR TO
OPERATING THE APPLIANCE.
NEVER VENT THE APPLIANCE INTO OTHER
ROOMS OR BUILDINGS. THE APPLIANCE
MUST BE VENTED ONLY TO THE OUTSIDE.
THIS
APPLIANCE
MUST
NOT
BE
CONNECTED TO A CHIMNEY FLUE SERVING
A
SEPARATE
SOLID-FUEL
BURNING
APPLIANCE.
DO NOT USE THIS HEATER IF ANY PART
HAS BEEN UNDER WATER. IMMEDIATELY
CALL A QUALIFIED SERVICE TECHNICIAN
TO INSPECT THE HEATER AND TO
REPLACE ANY PART OF THE CONTROL
SYSTEM AND ANY GAS CONTROL WHICH
HAS BEEN UNDER WATER.
Содержание PARLOUR 3000-MV
Страница 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...
Страница 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Страница 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...
Страница 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...
Страница 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...
Страница 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...
Страница 34: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 34 APPENDIX A VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...
Страница 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...