Thelin PARLOUR 3000-MV Скачать руководство пользователя страница 30

PARLOUR 3000-MV 

DIRECT VENT GAS HEATER 

 
 

 

30 

THELIN COMPANY LIMITED WARRANTY 

Thelin Co., Inc. warrants the Parlour 3000 Direct Vent Gas Heater against defects in material and workmanship for a period of five (5) 
years from the date of purchase with the exception of the electrical components, gaskets, logs, moving parts, gas valve and control, and 
burner which are warranted for a period of one (1) year from date of purchase. Glass, gasketing, gold plating, and paint are not covered 
by the warranty. This warranty does not include service call cost or any other additional charges. Check with dealer from who m the 
heater was purchased for all costs when arranging a warranty call

CONDITIONS 

This warranty is non-transferable and is made to the original purchaser only, provided that the purchase was made through an authorized 
dealer or factory-authorized sale. The appliance must be installed in accordance with the Installation and Operating instructions furnished 
with the product, as well as al local, state, and national building codes. Any alteration, abuse, accident, or misuse of the  product shall 
nullify this warranty. After sale service calls, adjustments, regular maintenance, cleaning and temporary repairs do not qualify for a 
service call or fee and are not covered. 

This warranty does not cover the surface finish—either paint or enamel—door gasket and window gasket. It does not cover installation 
or operational-related problems such as the use of corrosive driftwood (salt), downdrafts or spillage caused by environmental conditions 
(i.e., wind, nearby trees, buildings, hilltops, mountains, or inadequate venting), excessive offsets, or negative air pressure caused by 
mechanical  systems  such  as  furnaces,  fans,  clothes  dryers,  etc.  This  warranty  does  not  apply  to  the  venting  components,  hearth 
components

, or accessories used in conjunction with the installation of this product not manufactured by Thelin Co. Inc. 

THIS  LIMITED  WARRANTY  IS  THE  ONLY  WARRANTY  SUPPLIED  BY  THELIN  CO.,  INC.,  (UNLESS  AN  EXTENDED 
WARRANTY HAS BEEN PURCHASED) THE MANUFACTURER OF THE UNITS. ALL OTHER WARRANTIES, WHETHER 
EXPRESS  OR  IMPLIED,  ARE  HEREBY  EXPRESSLY  DISCLAIMED  AND  PURCHASER’S  RECOURSE  IS  EXPRESSLY 
LIMITED TO THE WARRANTIES SET FORTH WITHIN

HOW TO USE THIS WARRANTY: If you find this unit to be defective in material and/or workmanship within a period of five (5) 
years from the date of purchase, contact your local dealer from whom you purchased the heater. All warranty work must be authorized 
by the factory in advance of repair and an authorization number assigned. A warranty repair claim form must be signed by both the 
dealer and the customer. In the event your dealer is no longer in business or you cannot locate a dealer, you may do the following: Call 
or write factory, giving proof of purchase information and a narrative description of the defect together with your name and  address. 
Only the factory can authorize a heater or part return. Upon authorization by factory, return defective heater or part, freight prepaid to 
Thelin Company, Inc., Warranty Division, 12400 Loma Rica Drive, Grass Valley, CA 95945. Returned part or product will be repaired 
or replaced at Thelin Co.'s option and will be returned to you, freight prepaid, as soon as practical, but not later than 30 days after receipt. 

To register your Thelin Co., Inc. warranty, complete and sign the enclosed warranty card and mail it within ten (10) days from date of 
purchase. 

OTHER RIGHTS: This warranty provides you with certain legal rights. You may have additional rights, which vary from state to state 
in regard to this warranty. 

COMPLETE AND SAVE FOR YOUR RECORDS 

Date Purchased: _____________________________ 

Serial Number: _____________________________ 

Dealer/Retailer where Purchased: ______________________________________________________________ 

Thelin Company, Inc. reserves the right to change, without notice, product features or specifications described. 

Содержание PARLOUR 3000-MV

Страница 1: ...tructions CUSTOMER PLEASE KEEP INSTRUCTIONS FOR FUTURE REFERENCE INSTALLER PLEASE LEAVE THIS MANUAL WITH THE CUSTOMER PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION SAVE THESE INSTRUCTIONS Parlour...

Страница 2: ...led and maintained or a house fire may result For your safety follow the installation instructions Contact local building officials about restrictions and installation inspection Failure to comply wit...

Страница 3: ...E APPLIANCE BE KEPT CLEAN IT IS IMPERATIVE THAT CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE ARE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OU...

Страница 4: ...with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Listing and Codes The Parlor is listed and certified for i...

Страница 5: ...pection 24 Floor Protection 14 Gas Control Knob 21 Gas Data 14 Gas Leaks 2 7 Gas Line Installation 21 Gas Valve 33 Glass Replacement 26 Gold polishing 26 Hi Lo Flame Adjust 21 Horizontal Installation...

Страница 6: ...nts 18 Figure 6 Vent Termination 20 Figure 7 Location of Pilot Burners and Logs 22 Figure 8 Diagram of Control Components 23 Figure 9 Wiring Diagram 29 Figure 10 Directions for Enabling Door Opening a...

Страница 7: ...he vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT TRY TO LIGHT ANY APPLIANCE DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT TURN ON ANY LIGHTS OR LAMPS DO NOT USE ANY PHONE IN Y...

Страница 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...

Страница 9: ...sure you have the proper gas valve for the fuel being used The gas valve is clearly marked natural gas or LP gas This marking can be found on the back of the stove above the gas line see Figure 1 Perm...

Страница 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...

Страница 11: ...GAS HEATER 11 FIGURE 2 CLEARANCE TO COMBUSTIBLES Please use these diagrams to place your stove in the room Please note Cornerwall means from the back of the stove to the corner Unit to corner 10 Cente...

Страница 12: ...rants no warranty implied or stated for the installation and maintenance of your heater and assumes no responsibility of any consequential damages as a result of improper installation or failure to pe...

Страница 13: ...RMATION Factory installed orifices are as follows Natural Gas 39 up to 4 500 elevation LP Gas 53 up to 4 500 elevation Recommendation If installing at higher altitudes Thelin Co recommends at the disc...

Страница 14: ...om heater should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or...

Страница 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...

Страница 16: ...gulator assembly U S Installation Clearance in accordance with local installation codes and the requirements of the gas supplier I Clearance to service regulator vent outlet U S Installation Clearance...

Страница 17: ...r requirements For horizontal installations determine the minimum clearance from the rear of the appliance to the wall see the Listing Label It is also important to note the wall thickness Select the...

Страница 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...

Страница 19: ...les Any components with these symptoms must be replaced 2 Remove the termination cap and shine a flashlight down the vent pipe Remove any bird nests or other foreign material 3 Check for evidence of e...

Страница 20: ...nstallation involves a roof with a slope greater than 6 12 or if a wall or other vertical obstruction is within 8 of the vent termination the vent termination will have to be taller in accordance with...

Страница 21: ...essed it creates a spark at the pilot igniting it Burner On Off Switch This switch turns the burner on after the pilot is lit When the wall thermostat is hooked up this switch will remain in the On po...

Страница 22: ...nutes The pilot flame must cover the tip of the thermocouple and thermopile probes If the pilot flame does not sufficiently cover the probes it can be adjusted using the pilot adjustment screw found o...

Страница 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...

Страница 24: ...sound as the fan turns on These sounds are all normal WARNING Do not burn heater if glass is cracked or broken See Maintenance for replacing glass MAINTENANCE Make sure that there is adequate clearanc...

Страница 25: ...switch to ON position TO TURN OFF GAS TO APPLIANCE A This appliance has a pilot which is lit with a push button piezo lighter When lighting the pilot follow these instructions exactly BEFORE LIGHTING...

Страница 26: ...lass by slamming door or striking foreign object against glass Do not clean glass with abrasive cleanser or when hot Polishing the Gold and Chrome All gold and chrome plating used on the Parlour can b...

Страница 27: ...ned off The gas control valve is turned to pilot The gas control valve wasn t pushed in and or the igniter wasn t pushed repeatedly Main burner does not come on The pilot has gone out The burner on of...

Страница 28: ...only parts that the consumer may replace All other parts must be replaced by a qualified gas service person PART DESCRIPTION Door Gasket White 3 8 dia fiberglass rope 51 long Glass Gasket Tape Knit Hy...

Страница 29: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 29 FIGURE 9 WIRING DIAGRAM Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation...

Страница 30: ...ation of this product not manufactured by Thelin Co Inc THIS LIMITED WARRANTY IS THE ONLY WARRANTY SUPPLIED BY THELIN CO INC UNLESS AN EXTENDED WARRANTY HAS BEEN PURCHASED THE MANUFACTURER OF THE UNIT...

Страница 31: ...0 DIRECTIONS FOR ENABLING DOOR OPENING AND SECURING DOOR Cleaning Glass 1 Turn off stove and let cool down 2 Open door and clean glass with glass cleaner i e Windex or similar product and wipe with so...

Страница 32: ...1 DELAYED IGNITION SAFETY DOOR This unit is equipped with a safety door system that will prevent damage if the stove ignites with delayed combustion If this happens you must have a qualified service p...

Страница 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...

Страница 34: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 34 APPENDIX A VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...

Страница 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...

Страница 36: ...l rear log 2 against brick panel and center right to left 3 Place small log 3 with the notch on the bottom setting of the ledge indicated in the illustration 4 Rest the Y log 4 on top of the small log...

Страница 37: ...ATER APPENDIX C PYROTECH LOG PLACEMENT CONTINUED 5 Place the front log 5 against the Y log in the notch shown in the illustration with the bottom end up against the lip of the door opening Note The bo...

Страница 38: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER Thelin Hearth Products Inc 63 Laxalt Dr Carson City NV 89706 www thelinco com 775 241 2586...

Отзывы: