![Thelin PARLOUR 3000-MV Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/thelin/parlour-3000-mv/parlour-3000-mv_installation-and-operating-instructions-manual_1101486012.webp)
PARLOUR 3000-MV
DIRECT VENT GAS HEATER
12
Door and Logs
Always allow the heater to cool before carrying out
any maintenance or cleaning. The viewing door
should be opened for service only (see Maintenance
section). Do not place anything inside the firebox
area except authorized Thelin Hearth Products, Inc
factory log set. If the logs become damaged, replace
with factory-authorized logs. Never remove, replace,
modify, or substitute any part of this appliance unless
given instructions to do so by factory-trained
personnel or professionally licensed and certified gas
technicians.
Electrical Considerations
WARNING: Electrical Grounding Instructions. This
appliance is equipped with a three-pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a
properly-grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
This must be grounded in accordance with local
codes, or, in the absence of local codes, with the
National Electric Code ANSI/NFPA.
Safety Check Conclusion
Do not throw this Owner’s Manual away.
This
manual contains important hook-up, operation, and
maintenance instructions that you may need in the
future. Thelin Hearth Products, Inc, grants no
warranty, implied or stated, for the installation and
maintenance of your heater and assumes no
responsibility of any consequential damages as a
result of improper installation or failure to perform
routine maintenance.
SPECIFICATIONS
Listing Criteria, Lab Accreditation
See Listing Label (See Important Instructions
section) for laboratory listing criteria. When pressure
testing the gas supply at test pressures in excess of
1/2 psig (3.5kPa) you must isolate the heater from the
supply line by disconnecting or utilizing the gas shut
off valve.
Manifold Pressure
The heater has pressure taps located on the valve to
check the manifold pressure (see Figure 8). If the
manifold pressure does not match the following
pressure, check inlet pressure and correct the
problem:
Natural gas: High - 3.5” WC, Low – 1.7” WC
Propane:
High – 11.0” WC, Low – 3.5” WC
IMPORTANT INFORMATION
This appliance must be installed in accordance with all local codes, if any. If not, follow ANSI Z21.88-2019.
Installation codes, ANSI 223.1, NFPA 54, or current editions.
Please record the following information and keep this manual as a permanent document for your records in
case you require service in the future.
Model: (Check one)
Parlour 3000 Direct Vent Natural Gas
Parlour 3000 Direct Vent LP (Liquid Propane) Gas
Mail in your warranty card and save your bill of sale. You will need to show this evidence of date of purchase
to receive full warranty coverage.
Содержание PARLOUR 3000-MV
Страница 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...
Страница 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Страница 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...
Страница 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...
Страница 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...
Страница 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...
Страница 34: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 34 APPENDIX A VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...
Страница 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...