FIGURE 3 – BOTTOM VIEW SHOWING AIR SHUTTER AND LOCATION FOR PRESSURE
GAUGE INSERTION
(Burner must be removed to access air shutter)
ORIFICE INFORMATION
Factory installed orifices are as follows:
Natural Gas
=
#39 (up to 4,500’ elevation)
LP Gas
=
#53 (up to 4,500’ elevation)
Recommendation: If installing at higher altitudes, Thelin Co. recommends, at the discretion of the installer:
Natural Gas =
#40 (5,000’ to 7,000’ elevation)
LP Gas
=
#54 (5,000’ to 7,000’ elevation)
REMEMBER! The size of the orifice hole should be reduced the higher the elevation.