PARLOUR 3000-MV
DIRECT VENT GAS HEATER
14
Orifice Size
The orifices are factory installed for altitudes up to
4,500 feet. If installing in a higher altitude check the
orifice information (see Figure 3).
Electrical Rating
Room fan electrical rating is 115 V, 1.3 Amps, 60 Hz.
Dimensions
See Figure 1 for heater dimensions.
Gas Data
Input BTU:
Natural gas: 31,000 High, 18,600 Low
Propane:
28,000 High, 16,800 Low
Minimum Inlet Pressure:
Natural gas: 5.5” WC (Water Column)
Propane:
11.5” WC
Suggested Maximum Pressure:
Natural gas: 7” WC
Propane:
13” WC
INSTALLATION
Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a professional
service person. More frequent cleaning may be
required due to excessive lint from carpeting,
bedding, material, etc. It is imperative that control
compartments,
burners,
and
circulating
air
passageways of the appliance be kept clean.
Pipe Size
4” x 6-5/8”
Clearance to Combustibles (See Figure 2)
See Listing Label for clearance to combustibles. Due
to high temperatures, the room heater should be
located out of traffic and away from furniture and
draperies. Children and adults should be alerted to
the hazards of high surface temperature and should
stay away to avoid burns or clothing ignition.
Floor Protection
Floor protection is not required when installing the
Direct Vent stoves, but is recommended if placed on
carpet or any other soft material for the stove to
remain level. In addition, the following criteria must
be adhered to when installed:
1.
Install on level and secure floor.
2.
Due to high temperatures, the room heater should
be located out of traffic and away from furniture
and draperies.
3.
When placed in a location where the floor-to-
ceiling height is under 7’, the installation is
considered an alcove and must meet the
following criteria: Floor to ceiling of alcove must
be a minimum of 45”. The depth of the alcove
must be at least 27”.
Bedroom Installation
This Direct Vent appliance may be installed in a
sleeping room provided the wall thermostat option is
utilized.
Horizontal Installation
Maintain a 1” clearance from combustibles to pipe
through the wall. Check all local and national
building codes. Termination clearances are as
follows (see Figure 4).
A.
Clearance above ground, verandah, porch, deck,
or balcony: 12” minimum (30 cm.)
Содержание PARLOUR 3000-MV
Страница 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...
Страница 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Страница 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...
Страница 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...
Страница 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...
Страница 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...
Страница 34: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 34 APPENDIX A VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...
Страница 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...