PARLOUR 3000-MV
DIRECT VENT GAS HEATER
19
restriction disks. (See Appendix A).
Two 45-
degree elbows to offset the vertical rise are
permitted. Clearances to combustibles when passing
through ceilings, walls, roofs, enclosures, attic
rafters, or other close combustible surfaces are as
follows: 1” to pipe from any combustible surfaces.
Notes
1.
If an offset is necessary in the attic to avoid
obstructions, it is mandatory to support the vent
pipe every 3 feet, to avoid excess stress on the
elbows (see Figure 5). Vertical installations that
require offsets must use 45-degree elbows. The
45-degree elbows offer less restriction to the flow
of flue gasses and intake air.
2.
For multi-story vertical installations, a ceiling
firestop is required at the second floor, and any
subsequent floors.
3.
Any occupied areas above the first floor,
including closets and storage spaces that the
vertical vent passes through must be closed.
The enclosure may be framed and sheet rocked
with standard construction materials. Maintain
the clearance to combustibles inside the
enclosure as per the Listing Label. Do not fill any
of the air spaces with insulation.
4.
GENERAL VENTING MAINTENANCE
Conduct an inspection of the venting system semi-
annually. A periodic examination of venting
system should be done by a qualified agency.
Recommended areas to inspect are as follows:
1.
Check all areas of the venting system exposed to
the elements for corrosion. Corrosion will appear
as rust spots, streaks, and in extreme cases, holes.
Any components with these symptoms must be
replaced.
2.
Remove the termination cap and shine a
flashlight down the vent pipe. Remove any bird
nests or other foreign material.
3.
Check for evidence of excessive condensation
such as water droplets forming on the inner liner
or dripping from the pipe vent joints. Continuous
condensation can cause corrosion of caps, pipe,
and fittings. It may be caused by having
excessive lateral runs, too many elbows, and
exterior portions of the system being exposed to
cold weather.
4.
Inspect joints to ensure that no pipe sections or
fittings have been disturbed or loosened. Check
mechanical supports such as wall straps,
plumbers tape, etc., for strength, fastening, and
rigidity.
INSTALLATION CHECKLIST
Check off the following list before proceeding to
light the heater.
❑
There are no combustibles placed within 36” of
heater or vent pipe or any combustibles that can
swing within 36” of heater such as door drapes,
etc.
❑
The location of the main shut off valve is
known by everyone in the house (it is usually
next to the gas meter or propane tank).
EVERYONE must know where this valve is
located.
❑
All
necessary
permits
and
installation
information have been obtained and the final
inspection has been performed by the local
building inspector.
❑
The operation instructions located on the side
of the heat shield have been read and
understood. A copy of these instructions can be
found in the “Operation” section of this
manual.
❑
The operator and pilot igniter have read this
manual thoroughly and understand it.
If heater is removed from venting system it must
be attached and resealed per vent manufacturer
requirements and in accordance with this
installation manual.
Содержание PARLOUR 3000-MV
Страница 8: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 8 LABORATORY LISTING LABEL...
Страница 10: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 10 FIGURE 1 DIAGRAM OF DIMENSIONS...
Страница 15: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 15 FIGURE 4 VENT TERMINATION LOCATIONS...
Страница 18: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 18 FIGURE 5 DIAGRAM OF VENTING REQUIREMENTS...
Страница 23: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 23 FIGURE 8 DIAGRAM OF CONTROL COMPONENTS...
Страница 33: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 33 FIGURE 12 GAS VALVE AND PILOT ASSEMBLY...
Страница 34: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 34 APPENDIX A VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...
Страница 35: ...PARLOUR 3000 MV DIRECT VENT GAS HEATER 35 APPENDIX B PARLOUR STOVE WITH BURNER...