IOM CRUZcontrol®
P/N: 90480009
Revision Date: 03/18/2019
Page
36
of
58
Zone Status Function Module E0006306
All directions of upstream or downstream are given with respect to the Function Module.
Logic Interrupt / Stop Zone
Definition:
Breaks logic signal from downstream Logic Assembly. Upstream logic line is forced OFF
despite Downstream zone status.
Action:
Upstream zone accumulates when the upstream Logic Assembly detects a package.
Configuration: Apply a low (OFF) signal input to TB4 when JP4 is on 2-3. When configured for Logic
Interrupt/Stop Zone, removing power from the terminal causes a Logic Interrupt/Stop Zone
function.
Single Release
Definition:
Upstream logic line is turned ON.
Action:
Upstream Logic Assembly releases despite zone status.
Configuration: Apply a high (ON) signal input to TB4 when JP4 is on 1-2
Slug Release
Definition:
The Slug Release line is turned ON. This can occur by applying power (turning ON) the
slug line at any point in the CRUZcontrol system. The Function Module can be used to
supply power to the Slug Release Line.
Action:
All zones that are connected to the Slug line release regardless of zone status or
accumulation status.
Configuration: Apply power from an external source directly to the Slug Release Line at the Slug
connection on TB5. Power source must be sized appropriately to directly drive all
connected Logic Assemblies.
Zone Status Indication
Definition:
Indicates full or empty status of the downstream zone at two output locations.
Action:
Takes an input from one of several user selectable inputs and outputs to the ZS Relay on
TB3 and Zone Status Output on TB5.
Configuration: Choose the input that determines the zone’s empty or full status.
Downstream logic signal (identical to Downstream Sensor signal of a Single
Accumulation Logic Assembly) as the input:
JP4 is on 1-2 or 2-3 and JP5 is on 1-2 or NC.
Auxiliary sensor or external signal (from a PLC for example) as the input:
JP4 is NC and ON signal is input to TB4
Downstream Sensor as the input (available only on 5 wire Logic Assemblies):
JP4 is on 1-2 or 2-3 and JP5 is on 2-3