IOM CRUZcontrol®
P/N: 90480009
Revision Date: 03/18/2019
Page
12
of
58
NBA
®
23 to RLC
®
25 CRUZcontrol Installation
The accumulating option on your RLC 25 curve simply solves all previous problems associated with V-
belt driven curves. IT IS NOT NECESSARY TO CLEAR THE CURVE OF PRODUCT when accumulation
reaches it. There is no lost accumulation space since THE CURVE IS AN EXTENSION OF THE
FOLLOWING ACCUMULATION. When the zone following the curve accumulates, so does the curve.
THERE ARE NO CONTROLS YOU NEED TO SUPPLY.
No “full-line” photoeye is required following the curve. No special gaps need to be forced between
products entering the curve. THERE IS NO INDEXING OR OTHER DEVICES, MOTORS, CONTROLS
OR WIRING that need to be engineered or installed.
NOTE
A roller brake is recommended at the discharge end of any NBA®23 accumulation conveyor preceding
the curve, to prevent coasting products from impacting those in the curve.
The examples on the following page show plumbing for several possible configurations of the
accumulating option of the RLC 25 product line. Note that Example “C” illustrates the upstream NBA 23
beds with typical plumbing and controls shown.