IOM CRUZcontrol®
P/N: 90480009
Revision Date: 03/18/2019
Page
17
of
58
One Power Supply used to power two separate CRUZcontrol sections:
This drawing illustrates the use of one power supply to power two separate, short CRUZcontrol sections
on two different conveyors. This can be done to make better use of the full capacity of a power supply,
provided that the total number of Logic Assemblies doesn’t exceed 53. The number of CRUZcontrol
zones that can be connected per string must also be reduced according to the total length of wire and
cable used to reach the first CRUZcontrol Logic Assembly of the string (refer to chart under Power Supply
Requirements section).
TGW Systems Part Number
Description
224-201
Connectors
PS256ADAPT44B3
T Cable (one is already provided with Power
Supply Kits)
+
-
+24 VDC (Brown)
0 VDC (Blue)
24 VDC POWER
SUPPLY
24v
Conveyor 1
CRUZcontrol
circuit
Conveyor 2
CRUZcontrol
circuit
T CABLE
14 AWG WIRE
CONNECTORS
CONVEYOR FLOW