IOM CRUZcontrol®
P/N: 90480009
Revision Date: 03/18/2019
Page
18
of
58
Using two Power Supplies to power one extended CRUZcontrol string:
A CRUZcontrol string with more than 53 Logic Assemblies would require the use of more than one power
supply. This can be done, but it requires that the power supplies be isolated from each other at the +24
volt line. This drawing illustrates how to isolate the two strings making use of a Power Interrupt Cable.
The + VDC line, (pin 1), is not passed through, while the Slug Release and Singulation Release Signals
as well as DC common (0 vdc) are connected so as to pass the signals through uninterrupted.
TGW Systems Part Number
Description
ZPI-P1
Power Interrupt Cable, 8 inches long
Last CRUZcontrol
Logic Assembly
powered from Power
Supply 1
First CRUZcontrol
Logic Assemblies
powered from Power
Supply 2
POWER
INTERRUPT
CABLE
CONVEYOR FLOW