IOM CRUZcontrol®
P/N: 90480009
Revision Date: 03/18/2019
Page
31
of
58
Zone Status Indication
Definition:
Indicates full or empty status of the downstream zone.
Action:
Takes an input from one of two user selectable inputs and outputs to the Zone Status
Output on TB5.
Configuration: Choose the input that determines the zone’s empty or full status:
Downstream logic signal (identical to Downstream Sensor signal of a Single
Accumulation Logic Assembly) as the input: JP4 is on 1-2 or 2-3
Auxiliary sensor or external signal (from a PLC for example) as the input:
JP4 is NC and signal is input to TB4
Release Function Module
Technical Data
Interface to CRUZcontrol
ZLM1, WLR2100-D
Upstream connection
Female, M12, 4-PIN, 300 mm cable
Downstream connection
Male, M12, 4-PIN, 300 mm cable
Power
Supply voltage from daisy chain
18…30 VDC
Power consumption of ZIM
10 mA, no load
ZoneControl system power TB4 input
24…28 VDC typical. Limit values: 18…30 VDC
Input ratings
TB4 Power VDC, Common
24 VDC typical, 30 VDC max.
TB4 Release/Interrupt input
18…30 VDC
Guaranteed OFF Voltage: <= 4.0 VDC
Guaranteed ON Voltage: >= 15.0 VDC
Typical ON state current draw @24V: 4mA
TB1 Single Release/Logic Interrupt
1
18…250 UC
1
Guaranteed OFF Voltage: <= 4 UC
Guaranteed ON Voltage: >= 15.0 UC
Typical ON state current draw 2.5 mA
TB2 Slug Release input
1
18…250 UC
1
Guaranteed OFF Voltage: <= 4 UC
Guaranteed ON Voltage: >= 15.0 UC
Typical ON state current draw 2.5 mA
Output ratings
TB5 Logic output
PNP; 2.21 kohm impedance typical
TB5 Zone Status output
PNP; 2.21 kohm impedance typical
Physical properties
Terminal block
Terminal block wire
30 to 12 AWG (2.5 … 0.2mm², strip length ¼" (6.0 mm)
Screw terminal torque
5 in-lbs. (0.56 Nm)
Housing
Dimensions
5.125" x 3.75" x 1.125" (130mm x 95mm x 29mm)
Mounting
3/16" holes in mounting flange or double sided adhesive, any orientation
Enclosure rating
IP 42, NEMA 1
Sock and vibration
IEC 68 2-27, IEC 68 2-29, and EC 68 2-6
Operating temperature
-13…131°F (-25…55°C)
Storage temperature
-40…185°F (-40…85°C)
Approximate weight
0.9 lb. (400 g)
1. These inputs are optically isolated from the rest of the Class 2 circuitry. Isolation voltage from Universal-Voltage
inputs to Class 2 circuitry: 5000Vrms. Inputs are not sensitive to polarity.
2. Optically isolated solid state relay with 1 Normally Open and 1 Normally Closed contact. Isolation voltage from
ZONE STATUS relay terminals to Class 2 circuitry: 5000Vrms