8
IMON Out
I MON OUT
Current monitor BNC terminal: Output
connector used to monitor the current
by outputting a voltage.
An output voltage of 10V corresponds
to the full scale current for the H and
L ranges. 1V corresponds to the full
scale current in the M range.
VMON Out
V
MON OUT
Voltage monitor BNC terminal:
Output connector used to monitor the
voltage by outputting a voltage. An
output voltage of 8V corresponds to
the full scale voltage.
TRIG OUT
TRIG OUT
Trigger out BNC terminal:
Outputs a pulse signal during
sequence or dynamic operation. The
trigger signal has a 4.5V output with a
pulse width of a least 2us and an
impedance of 500Ω.
LINK/STBY
Indicator
(LSG-2100H)
LINK
STBY
The LINK and STBY indicators
indicate when the booster pack is
properly connected and when the
power has been turned on,
respectively.