189
7-7-13. Sequence
Normal Sequence
Operation mode
CC, CR, CV, CP
Maximum number of steps
1000
Step Execution Time
0.05ms ~ 999h 59min
Time resolution
0.05 ms (0.05ms ~1 min)
100 ms (1 min ~1 h)
1 s (1 h ~10 h)/10 s (10 h ~100 h)
1 min (100 h ~999 h 59 min)
Fast Sequence
Operation mode
CC or CR
Maximum number of steps
1000
Step Execution Time
25us
– 600ms
Time resolution
1us(25us - 60ms)
10us(60.01ms - 600ms)
7-7-14. Other
Elapsed Time Delay
Measures the time from load on to load off. On/Off selectable.
Measures from 1s up to 999h 59min 59s
Auto Load Off Timer
Automatically turns off the load after a specified time elapses.
Can be set in the range of 1s to 999h 59min 59s or off
Communication Function
GP-IB
IEEE std. 488.1-1978 (partial support)
SH1, AH1, T6, L4, SR1, DC1, DT1.
Supports the SCPI and IEEE std. 488.2-1992 command set
Sets panel functions except the power switch and reads
measured values
RS-232C
D-SUB 9-pin connector (conforms to EIA-232-D)
Sets panel functions except the power switch and reads
measured values
Supports the SCPI and IEEE std. 488.2-1992 command set
Baud rate: 2400, 4800, 9600, 19200, 38400 bps
Data length: 8-bit, Stop bit: 1, 2-bit,
Parity bit: None, Odd, Even.
USB
Conforms to USB 2.0 Specifications and USB-CDC ACM
Sets panel functions except the power switch and reads
measured values
Communication speed 12Mbps (Full speed)
Содержание LSG-1050H
Страница 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Страница 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Страница 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Страница 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Страница 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Страница 204: ......